Maintained/non-maintained (optional) luminaire

Advertisement

Quick Links

GR-2000
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES Ni-Cd
(
)
BATTERY PROTECTION
INDICATIONS CONTROLS
-
CHARGING TIME
AUTONOMOUS DURATION
ILLUMINATION SOURCE
ILLUMINATION SOURCE INTENSITY
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
GENERAL
The
luminaires
of this type cover
functionality in security lights, for professional
or household use.
They have features such as:
1. Change function from
non-maintained
or vice versa, whenever
desired.
2. Light sensor to select the activation or not
of
the l
uminaire, when it is connected to the
mains power supply,
lighting in the area.
3.
Dimming control
4. Possibility of remote control
functions and additional functions are
analyzed on page 3.
The functions 1,2 and 3 may be
using the TEST button as explained on page
3.
T h e
l u m i n a i r e
m u s t b e p e r m a n e n t l y
connected to the mains
normal operation
it
lights the LED lighting (
a n y p o w e r f a i l u r e t h e l
automatically switched to
lighting the LED lighting
When
the mains power supply is restored the
unit
returns to normal operation.
Charging the Battery
The
charging of the
by the
luminaire
to achieve optimal battery
maintenance, and prolong
battery is fully charged, the charging current is
limited
for
maintenance.
Page 1 from 4
'' SLIM LIGHT '' SERIES FOR MAINTAINED / NON-MAINTAINED
TECHNICAL CHARACTERISTICS
Charge (green), lamp fault (red), fault (orange) indication LED TEST button
EN 60598-1, EN 60598-2-22, ÅÍ 55015, ÅÍ 61547, ÅÍ 61000-3-2, ÅÍ 61000-3-3
the
standard
maintained
to
if there is adequate
(with remote
control
).
for
implemented
power supply
. During
charg
es
the battery and
maintained
mode). In
u m i n a i r e
emergency
from the
battery.
battery is fully controlled
ed
life. When the
(OPTIONAL) LUMINAIRE
220-240V AC/50-60Hz
From overcharge and full discharge
3-7 hours depending on the illumination adjustment of the LED's
110lm (230V AC) / 110lm (emergency)
Bayblend F 3010 transparent polycarbonate
R
270 x 100 x 25 mm
3 years
Battery
cut off
The
luminaire enters
power supply
lost all its energy. The consumption of all
lighting circuits is limited to the minimum
needed to protect the battery from deep
discharge.
Manual
Test
Manual
testing
Test button
driv
ing
circuit . To
unit
should be
supply
and the battery
these
During the test
Automatic
It
includes
automatically every 15 days. To
operation,
mains power supply
enabled.
Automatic
The automatic duration test
autonomy of the emergency operation of the
i s
device. This
mode,
every 6 months. To
unit
should be
supply
and the battery
f u l l y c h a r g e d , o t h e r w i s e t h e c h e c k i s
postponed
Backup Status Operation
The
duration
is
at least
During the backup operation
also performed
4W
3.6V/1Ah
24h
White LED's
IP 40
o
0 to 40 C
Up to 95%
,
340gr.
(1
year for the battery
)
this state when the mains
is interrupted and the battery has
is performed by pressing the
to
check the LED lighting and the
perform this operation,
connected to the mains power
must be enabled
the orange
LED
LED Test
all
manual
tests
but
the
unit
should be
connected to the
and the battery
duration test
test
is performed automatically
perform this operation,
connected to the mains power
must be enabled
until the battery is fully charged.
of battery life in
emergency
that specified in the table above.
.
923200000_09_003
S A A R
CE
RT
CERTIFICATE
VALID SYSTEM
EN ISO 9001 : 2008
,
the
.
blinks
.
is conducted
perform this
must be
measure
s
the
the
and
mode
an LED test is

Advertisement

loading

Summary of Contents for olympia electronics SLIM LIGHT Series

  • Page 1 S A A R CERTIFICATE VALID SYSTEM EN ISO 9001 : 2008 ‘’ SLIM LIGHT ‘’ SERIES FOR MAINTAINED / NON-MAINTAINED GR-2000 (OPTIONAL) LUMINAIRE TECHNICAL CHARACTERISTICS OPERATION VOLTAGE 220-240V AC/50-60Hz MAXIMUM POWER CONSUMPTION BATTERIES Ni-Cd 3.6V/1Ah BATTERY PROTECTION From overcharge and full discharge INDICATIONS CONTROLS Charge (green), lamp fault (red), fault (orange) indication LED TEST button CHARGING TIME...
  • Page 2 Indication LED status NOTE: LED= Light Emitting Diode status of the indication LEDs is described in the diagram below. LABELING EXPLANATION: X: Self contained ÁÔÔÅÍÔÉÏÍ!!! 1: Maintained 1. Operations for installation, maintainance or A: Including test device testing must be done by authorized personel 180: 3 hour duration only INSTALLATION...
  • Page 3 GR-2000 WITH REMOTE CONTROL OPERATIONS OF REMOTE CONTROL IRT200 (for models that support remote control). (To operate the remote control you must first remove the transparent protective battery insulator from the bottom of the device). Explanation of function keys: 1. Button ights luminaire when operating in...
  • Page 4 Performed by continuous pressing the button for 10 seconds. The following will occur when the button is pressed Within 5 seconds the faults are cleared (the 3 indication LEDs light se quentially) and at the end of the 10 seconds the green and red LEDs stay on When these LEDs stay on release the test button and the luminaire will operate as maintained or non-maintained depending on the previous mode of operation.

This manual is also suitable for:

Gr-2000