RETURN AIR DIVERTERS

1. Lift the front end of the diverter and slide the
clips up and behind the oven's rear wall.
2. Lower the front end and slide the diverter into
place. The diverters must be installed in the
correct order. See Figure 4.
NOTE: Be sure the edges of the left and right div-
erters line up with the cutout in the rear
oven wall.
Inner Diverter
Left Diverter
Top View
Clip
Left Diverter
Inner Diverter
Air Diverters --- Bottom View
Figure 4

NOZZLES

1. Install the nozzles from center of the oven
2. Secure the nozzle hold-down strip across the
Right Diverter
Right Diverter
7
Installation
working towards the ends. Make sure the bot-
tom of the air nozzle fits into the slot in the
nozzle support located at the front of the oven.
See Figure 5 for correct nozzle location.
inside front of the oven using the existing
screws located on the oven wall.
Nozzle M7105 ---
1 hole in flange at
open end
Top View
Figure 5
Oven Assembly
Nozzle M7106 ---
2 holes in flange
at open end
M7105
M7106