MAYSER SG-EFS 1 4 ZK2/1 L20ms Series Operating Instructions

Safety control unit

Advertisement

Quick Links

Safety Control Unit SG-EFS 1X4 ZK2/1 L20ms
with automatic or manual reset
Reset
SG-EFS 1X4 ZK2/1 L20ms
Auto-
channel
channel
Reset
1
2
fault indicator
relay
sensor
Operating
Instructions
Safety Control Unit with
EEC-type-examination
certificate
EN 954 Category 3
with forceguided contacts for increased
safety requirements;
for Pressure Sensitive Mats, Safety
Edges and Safety Bumpers with
1.2 kΩ monitoring resistor.
These operating instructions apply to
the following control units:
SG-EFS 104 ZK2/1 L20ms
SG-EFS 134 ZK2/1 L20ms 230 V~

Control

The single-fault-safe electronics module
has two channels (redundant).
Each channel triggers a force guided
relay. The relays self-test by contact
return after each switching cycle. The
electronics monitor the electrical resi-
stance of the connected sensors which
have a specific closed-circuit current.
When the sensors are not activated,
both output relays are energized and
both yellow LEDs light. If a sensor is
activated, or a break occurs in the sup-
ply to the control unit, relays K1 and K2
deenergize and the LEDs go out.
Erroneous tripping signals, caused by
falling material, are prevented by 20 ms
by means of a time element.

Enclosure

W × H × D (mm)
45 × 75 × 105
Protection class
Plug-in connectors
each 8-channel
Cable clamps
max. 2.5 mm
Weight
= model
approx. 175 g
~ model approx. 270 g
Notes on protection class:
The units may only be used in locations
with a minimum protection class of
IP 54 (eg. cabinet).

Parts supplied

- Control Unit
Enclosure with electronics module and
plug-in connectors.
- Operating Instructions
24 V=/~
IP 20
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG-EFS 1 4 ZK2/1 L20ms Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MAYSER SG-EFS 1 4 ZK2/1 L20ms Series

  • Page 1 Safety Control Unit SG-EFS 1X4 ZK2/1 L20ms Operating with automatic or manual reset Instructions Safety Control Unit with EEC-type-examination certificate EN 954 Category 3 with forceguided contacts for increased safety requirements; for Pressure Sensitive Mats, Safety Edges and Safety Bumpers with 1.2 kΩ...
  • Page 2 Safety Control Unit SG-EFS 1X4 ZK2/1 L20ms IMPORTANT NOTES! Please read! To ensure correct and safe operation This unit is constructed and tested to When using the device outside the of the unit, it must be properly trans- prEN 1760 and DIN V 31006 and left our European Union, you must observe ported and stored, properly installed factory in perfect condition with regard...
  • Page 3 Installation and Operation Installation Commissioning The enclosure of the control unit can be After connecting up sensors, switching mounted in any position: contacts and power, carry out a function - on a 35 mm EN 50022 rail test in the following order: Sensor not activated Wiring is carried out in the cable clamps 0.1A...
  • Page 4 Check sensor Check combination of sensors control Resistance measurement: sensor unit Disconnect power to the unit. Unplug plug-in connection and measure (Y1,Y2) with an ohmmeter: not activated c. 1.2 kΩ < 150 Ω activated If the values measured deviate consi- derably from the set values, the sensors have to be checked individually (see below).

This manual is also suitable for:

Sg-efs 104 zk2/1 l20msSg-efs 134 zk2/1 l20ms

Table of Contents