Mediblink Ear Thermometer M300 INSTRUCTIONS FOR USE PLEASE READ THE INSTRUCTIONS FOR USE CAREFULLY BEFORE USING THE PRODUCT...
Page 2
Summary of Important Instructions for Temperature Measurement Introduction Safety Instructions Before Use of the Product Body temperature information Description of Product Components Description of Symbols on LCD Screen Inserting Batteries Switching Between Degrees Celsius and Fahrenheit Advice for Measuring Personal Body Temperature Ear Measurement of Body Temperature Memory Care and Maintenance...
Page 4
Summary of Important Instructions for Temperature Measurement These are important 2-page instructions. Please read the instructions thoroughly before use. 1. Study results show that the ear is ideal for measuring body temperature, since the hypothalamus (brain part regulating body temperature) and the eardrum are supplied by the same blood vessels.
Page 5
Summary of Important Instructions for Temperature Measurement 10. If you are using ear drops or any other medicine in one ear, you should measure the temperature in the other ear. 11. If you have been lying on one ear for a longer period of time, the temperature in this ear will be slightly higher.
Page 6
Introduction Using infrared technology, the thermometer measures the temperature in approximately one second. The product complies with the EC provisions and MDD Directive (93/42/EEC). The product features are: 1. Intended use: for clinical, hospital, or home measurement of body temperature. 2.
Page 7
Safety Instructions Before Use of the Product Make sure to follow all of the instructions below when using the product. Any failure to follow the instructions may result in injury or affect the accuracy of the measurement. Warning! Potential risks for children and people with reduced physical, sensory, or mental abilities! 1.
Page 8
Safety Instructions Before Use of the Product 7. Avoid improper use. 8. This thermometer cannot replace a consultation with a physician, or medical treatment! The measurement results are for comparison purposes only. In the event of a medical problem, you should see your physician. 9.
Page 9
Safety Instructions Before Use of the Product 18. Always measure the temperature in the same ear, as it can differ between both ears. 19. If you are using ear drops or any other medicine in one ear, you should measure the temperature in the other ear. 20.
Page 10
Safety Instructions Before Use of the Product 4. If there is an interference or damage, do not open the thermometer or try to fix it yourself. Doing so would void the warranty claim. Only authorised persons are allowed to repair the thermometer.
Page 11
Body temperature information Body temperature is the internal body temperature (core temperature). It fluctuates during the day: it is lowest in the morning and highest in the late evening. Normal body temperature is not a definitive value but a range. Normal body tempera- Normal body tempera- ture in °C...
Page 12
Description of Product Components Thermometer tip with a measurement sensor Thermometer power and ear mea- surement button Memory recall button LCD screen Battery compart- ment cover Description of Symbols on LCD Screen Memory symbol and stored Measured tempera- measurement serial number ture Degrees Celsius...
Inserting Batteries Warning! Risk of explosion! Improper handling of batteries may result in explosion. 1. Only replace batteries with equal batteries or batteries of an equivalent type. 2. Do not expose batteries to excessive heat such as the sun or fire. 3.
Page 14
Inserting Batteries Low battery warning Before the batteries are completely empty, the “ ” symbol appears on the screen. You can still use the thermometer while this symbol is displayed, but we recommend that you replace the batteries as soon as possible.
Page 15
Inserting Batteries Disposal Disposal of packaging For disposal, separate the packaging by the type of material. For disposal, handle paperboard and cardboard as waste paper, and the foil as secondary raw materials. Disposal of waste product (Applicable to the European Union and other European countries with systems for separate collection of secondary raw materials.) Waste devices may not be disposed together with household waste!
Page 16
Switching Between Degrees Fahrenheit and Celsius The thermometer can display results in both degrees Celsius (°C) and Fahrenheit (°F). To switch between degrees Celsius and Fahrenheit, make sure the device is turned on, press and hold the Thermometer power/Temperature measurement button, and right after that, press the Memory button to change between °C and °F.
Page 17
Advice for Measuring Personal Body Temperature 1. Wait a little before starting to measure, if the thermometer has been stored at a location where the temperature is considerably different from the place of measurement. 2. The thermometer and persons whose body temperature you are measuring should be in the same room for at least 30 minutes.
Page 18
Advice for Measuring Personal Body Temperature 12. It is not allowed to use the same thermometer for multiple persons in the case of specific acute infectious diseases due to the possibility of bacteria or virus spread, despite cleaning and disinfection. If you have any doubts about using the thermometer, please consult your physician.
Page 19
Ear Measurement of Body Temperature 1. By pressing the “Thermometer power button”, the thermometer is switched on. As soon as the device is switched on, the machine will automatically perform a self-test. All symbols will be displayed on the screen. When the thermometer is ready for use, you will hear two short beeps.
Page 20
Ear Measurement of Body Temperature 7. Carefully remove the thermometer tip from the external ear canal and read the measured temperature from the LCD screen. 8. After approximately 1 minute, the thermometer will turn off automatically. Before that, you will hear a short beep. 1.
Page 21
Memory You can view up to 10 saved measurements to show to your GP. 1. When the device is switched off, press the “Memory recall” button. Press the same button again to recall the last saved measurement marked with the “ ”...
Care and Maintenance • Thermometer tip and measurement sensor For accurate measurement results, it is very important that the infrared thermometer sensor is clean and has no scratches. Before each measurement, check the infrared sensor and, if necessary, gently clean it with a cotton swab dipped in rubbing alcohol, and dry it with a clean, dry cotton swab.
Page 23
Before use, read the instruc- address tions for use Electronic instructions for use: EU Representative http://www.mediblink.com/f/ m300.pdf The device is rated IP 22, which means it is protected IP 22 Product reference number against water and dust particles entering the device...
16°C and 35°C (60.8°F and 95.0°F). Technical Specifications • Mediblink Ear Thermometer M300, model TS29 • Measurement method: infrared measuring • Measurement duration: approx. 1 second • Screen display: LCD screen with blue illumination, display of °C (degrees Celsius) or °F (degrees Fahrenheit)
EMC tables Guidance and manufacturer's declaration-electromagnetic emission The TS29 IR Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the TS29 IR Thermometer should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment guidance...
Page 26
EMC tables Guidance and manufacturer's declaration-electromagnetic immunity The TS29 IR Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the TS29 IR Thermometer should assure that it is used in such an environment. IEC 60601 Immunity Compliance...
Page 27
EMC tables Recommended separation distances between portable and mobile RF communications equipment and the TS29 IR Thermometer The TS29 IR Thermometer Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the TS29 IR Thermometer can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the TS29 IR Thermometer as recommended below, according to the maximum output power of the...
Warranty Product: Mediblink Ear Thermometer M300 Manufacturer: AViTA (Wujiang) CO., LTD, No.858. JiaoTong Road, Wujiang Economic Development Zone, JiangSu, P.R.C. Sellers name, address, signature and stamp: Date of extradition/sales: WARRANTY TERMS Dear customers! The warranty period is 5 years and starts from the day of product purchase.
Page 29
In case of product claim, call us on [PHONE NO.] or send us an e-mail on [EMAIL]. Manufacturer: Manufactured for AViTA (Wujiang) CO., LTD (EU importer): No.858. JiaoTong Road Mediblink d.o.o. Wujiang Economic Development Zone Gubčeva cesta 19 JiangSu, P.R.C. 8210 Trebnje Slovenia Wellkang Ltd.
Need help?
Do you have a question about the M300 and is the answer not in the manual?