Jedmed PHOENIX III Product Information / Technical Service Manual

Jedmed PHOENIX III Product Information / Technical Service Manual

Treatment chair

Advertisement

Available languages

Available languages

Product Information / Technical Service Manual
JEDMED PHOENIX III Treatment Chair
L'information de produit/manuel d'entretien technique technique
Chaises de traitement de la série JEDMED Phoenix III
IMPORTANT: Read all instructions before assembling or operating this device.
JEDMED INSTRUMENT COMPANY
5416 JEDMED CT.
ST. LOUIS, MO 63129-2217
PHONE (314) 845-3770
FAX (314) 845-3771
DOC. 9810
Email info@jedmed.com
1
REV. F, 12/05/14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PHOENIX III and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Jedmed PHOENIX III

  • Page 1 Product Information / Technical Service Manual JEDMED PHOENIX III Treatment Chair L'information de produit/manuel d'entretien technique technique Chaises de traitement de la série JEDMED Phoenix III IMPORTANT: Read all instructions before assembling or operating this device. JEDMED INSTRUMENT COMPANY 5416 JEDMED CT.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS: COVER PAGE TABLE OF CONTENTS PRODUCT DESCRIPTION APPLICATION OF PRODUCT SYMBOLS SAFETY PRECAUTIONS 8-10 SAFETY WARNINGS / DESCRIPTION OF PRODUCT GENERAL INFORMATION 12-13 SPECIFICATIONS / TRANSPORTATION / DISPOSAL UNPACKING / POWER REQUIREMENTS INSTALLATION INSTRUCTIONS / ANCHORING CHAIR OPERATION / INITIALIZING / PROGRAMMING CHAIR OPERATION / MEMBRANE HAND CONTROLS 18-19 CHAIR OPERATION / HEADREST OPERATION...
  • Page 3 DESCRIPTION JEDMED PHOENIX III ENT CHAIR THE JEDMED PHOENIX III ENT CHAIR WAS DESIGNED SPECIFICALLY WITH THE ENT PHYSICIAN IN MIND. IT WAS DEVELOPED BY COMBINING THE CLASSIC DESIGN OF PREVIOUS MEDICAL AND DENTAL CHAIRS WITH YEARS OF INDEPENDENT RESEARCH, EXPERIENCE AND THE LATEST TECHNOLOGY.
  • Page 4 ELIMINATING THE POSSIBILITY OF INCORRECT WIRING WHEN REPLACING COMPONENTS. MOTORS ARE THERMALLY PROTECTED. THE PHOENIX III IS MANUFACTURED IN THE USA. THIS IS A QUALITY DESIGNED AND MANUFACTURED MEDICAL DEVICE WHICH, WHEN GIVEN REASONABLE CARE, WILL PROVIDE MANY YEARS OF TROUBLE FREE SERVICE.
  • Page 5: Application Of Product

    JEDMED INSTRUMENT COMPANY HAS SPENT YEARS DESIGNING AND DEVELOPING THE PHOENIX SERIES ENT EXAM/TREATMENT CHAIRS . THE FOLLOWING ARE UNIQUE FEATURES THAT MAKE THE PHOENIX III CHAIRS THE MOST ADVANCED AND FUNCTIONAL TREATMENT/EXAM CHAIR AVAILABLE. 1- STANDARD PROGRAMMING ON THE CHAIR ALLOWS THE OPERATOR TO PROGRAM 3 POSITIONS THAT CAN BE RECALLED AT ANY TIME AND FROM ANY POSITION BY SIMPLY PRESSING ONE BUTTON.
  • Page 6: Symbols

    SAFETY WARNING SYMBOLS SYMBOLES D'AVERTISSEMENT DE SÛRETÉ MAIN POWER ON MAIN POWER OFF MAINS-POWER-ON MAINS-POWER-OFF EARTH GROUND PROTECTIVE EARTH ÉCHOUEMENT TERRE GROUND PROTECTION ÉCHOUEMENT TERRE CAUTION: RISK OF CAUTION: GENERAL DANGER ELECTRICAL SHOCK ATTENTION:DANGER ATTENTION: RISQUE DE CHOC ÉLECTRIQUE NORMAL OPERATION TYPE B EQUIPMENT TEMPERATURE RANGE.
  • Page 7: Safety Precautions

    émissions ou l'immunité diminuée de la chaise de PHOENIX III. 4. La chaise PHOENIX III ne devrait pas être employée à côté de ou empilée avec l'autre équi- pement, et cela si à côté de ou l'utilisation empilée est nécessaire, la chaise de PHOENIX III devrait être observée pour vérifier l'opération normale dans la configuration dans la-...
  • Page 8: Safety Warnings / Description Of Product

    SAFETY WARNINGS THIS PRODUCT HAS BEEN DESIGNED AND TESTED WITH YOUR SAFETY IN MIND. IMPROPER USE CAN RESULT IN ELECTRIC SHOCK OR OTHER PHYSICAL INJURIES. DO NOT DEFEAT THE SAFEGUARDS THAT HAVE BEEN DESIGNED INTO THIS PRODUCT. PLEASE READ AND OBSERVE THE FOLLOWING SAFETY POINTS WHEN INSTALLING AND OPERATING THIS PRODUCT AND SAVE THIS MANUAL AND ALL SUPPLEMENTAL LITERATURE FOR FUTURE REFERENCE.
  • Page 9 PROTECTION DE CORDON DE SECTEUR : DES CORDES D'ALIMENTATION D'ÉNERGIE DEVRAIENT ÊTRE CONDUITES AINSI QU'ELLES N'EN SONT PAS MARCHÉES DESSUS OU NE SONT PAS PINCÉES PAR L'AUTRE ÉQUIPEMENT PLACÉ SUR OU CONTRE EUX. UNE ATTENTION PARTICULIÈRE DE SALAIRE AUX CORDES AUX PRISES, RÉCEPTACLES DE CONVENANCE, ET OÙ...
  • Page 10 DO NOT SERVICE THE CHAIR WHILE A PATIENT IS IN THE CHAIR. PAS SERVICE LA CHAISE TANDIS QUE LE PATIENT EST DANS LA CHAISE. DESCRIPTION OF PRODUCT MODEL: FEATURES: PHOENIX III POWER BACK, POWER LIFT BASE. THREE PROGRAMMABLE POSITIONS. HEADREST OPTIONS. FOOT CONTROL OPTION.
  • Page 11: General Information

    BASE: CANTILEVERED LIFT - 14” (355mm) BACK: ELECTRIC ACTUATOR LEG: SYNCHRONIZED WITH BACK NET WEIGHT PHOENIX III 405 POUNDS, (184 kg) ELECTRICAL 24V D.C. LOW VOLTAGE MOTORS MICROPROCESSOR CONTROLLED CHAIR OPERATES AT 24V D.C. POWER SUPPLY 115VAC 60HZ 5A OR 230VAC 50HZ 5A CHECK SERIAL TAG FOR REQUIRED VOLTAGE.
  • Page 12 PRODUCT SPECIFICATIONS PHOENIX III AGENCY: Standard for Medical Electrical Equipment, Part 1: General Requirements for Safety (UL 60601-1, 1st Edition, Dated 04/25/2003 with revisions through 04/26/2006 and CAN/CSA-C22.2 No. 601.1-M90, 11/03) ETL 46979 72in 183c m 22in 18in 24in 56c m...
  • Page 13 DISPOSAL OF EQUIPMENT DISPOSAL OF JEDMED EQUIPMENT: The JEDMED chair model PHOENIX III and equipment removed from service should be dis- posed of in accordance with local regulatory requirements. Circuit boards and electrical cabling should be recycled as electrical salvage. Plastic parts should be recycled accordingly. Any materi- al unsuitable for recycling should be disposed of appropriately.
  • Page 14 UNPACKING PRE ASSEMBLY CHECK UNPACK SHIPPING CARTONS CAREFULLY AND CHECK TO SEE THAT ALL PARTS ARE RECEIVED AND HAVE NOT BEEN DAMAGED DURING SHIPPING. CAUTION: CHAIR SHOULD BE LIFTED FROM BELOW MAIN SEAT FRAME. DO NOT AT ANYTIME MOVE CHAIR BY LIFTING ON BACK, TOE SECTION, OR ARMS.
  • Page 15: Installation Instructions / Anchoring

    INSTALLATION INSTRUCTIONS / ANCHORING PHOENIX III MODELS: LOCATION: INSURE THAT SELECTED LOCATION IS ADEQUATE TO ALLOW THE CHAIR TO SWIVEL 355 DEGREES. SEE PAGE 13 NOTE: BASE MUST BE ANCHORED TO FLOOR. FAILURE TO DO SO MAY RESULT IN SERIOUS BODILY INJURY TO OPERATOR AND/OR PATIENT AND COULD CAUSE UNWARRANTED PRODUCT DAMAGE.
  • Page 16 OPERATING YOUR PHOENIX III CHAIR INITIALIZING CHAIR MOTORS: AFTER INSTALLATION, RUN BACK DOWN COMPLETELY AND CHAIR BASE UP COMPLETELY. RETURN CHAIR TO THE “HOME” POSITION USING THE “HOME” FUNCTION. THIS COMPLETES INITIALIZATION. PROGRAMMING INSTRUCTIONS: READ THESE INSTRUCTIONS COMPLETELY BEFORE YOU BEGIN PROGRAMMING.
  • Page 17 OPERATING YOUR PHOENIX III SERIES CHAIR (CONTINUED) MEMBRANE HAND CONTROL OPERATION RETURN TO HOME Press and release to have the chair return to the patient exit position. MEMORY POSITIONS Press to have the chair go to a programmed position. SAVE See note below.
  • Page 18 OPERATING YOUR PHOENIX III SERIES CHAIR (CONTINUED) HEADREST RELEASE (ALL MODELS) HEADREST HEIGHT ADJUSTMENT: TO LOWER OR RAISE THE HEADREST; SUPPORT THE HEADREST WITH ONE HAND AND PUSH THE RELEASE LEVER DOWN WITH THE OTHER. LOWER OR RAISE THE HEADREST TO DESIRED HEIGHT.
  • Page 19 OPERATING YOUR PHOENIX III SERIES CHAIR (CONTINUED) HEADREST OPERATION FLIP LOCKING LEVER AWAY FROM THE BODY OF THE MECHANISM TO ALLOW HEADREST ARTICULATION. TO LOCK IN POSITION, PUSH LEVER BACK TO ORIGINAL LOCKING POSITION. WHEN POSSIBLE ADJUST THE HEADREST BEFORE SEATING PATIENT.
  • Page 20 OPERATING YOUR PHOENIX III SERIES CHAIR (CONTINUED) PATIENT ARM: RELEASING AND LOCKING ARM RELEASE TAB PATIENT ARMS HAVE BEEN DESIGNED TO DROP FORWARD AND OUT OF THE WAY FOR EASIER PATIENT ENTRY OR EXIT. TO LOWER THE ARM; SUPPORT THE ARM AT FRONT. DEPRESS THE FINGER TAB AND LOWER THE ARM.
  • Page 21 OPERATING YOUR PHOENIX III SERIES CHAIR (CONTINUED) MIRROR LIGHT OPERATION / FIELD INSTALLATION 6” PIC. 1 PIC. 2 WARNING: ELECTRICAL SHOCK HAZARD - DISCONNECT THE AC POWER CORD TO THE CHAIR. AVERTISSEMENT RISQUE DE CHOC ÉLECTRIQUE - Débranchez l'alimentation électrique avant d'effectuer un service ou de réparation.
  • Page 22 Sunnex HS Series Lights SHADE REMOVAL FOR HS SERIES BULB REPLACEMENT ON LAMPS PURCHASED AFTER 7/1/2007 **BE SURE THAT LAMP HAS COOLED SUFFICIENTLY PRIOR TO PERFORMING BULB REPLACEMENT** 1) Before changing light bulb, set switch to off position and/or unplug lamp cord from wall socket.
  • Page 23 OPERATING YOUR PHOENIX III SERIES CHAIR (CONTINUED) FOOT CONTROL INSTALLATION/OPERATION (FOOT CONTROL IS OPTIONAL) -BASE MUST BE PRE-WIRED AT THE FACTORY FOR THE FOOT CONTROL OPTION- REMARQUE: Base de mut être précâblés en usine pour l'option commande au pied. CONNECT FOOT CONTROL CABLE...
  • Page 24: Cleaning / Infection Control / Maintenance / Service Facilities Electrical Components Diagram 115Vac/230Vac

    DEVRAIENT ÊTRE EXAMINÉS CONFORMÉMENT AUX RECOMMANDATIONS DE FABRICANTS TECHNICAL SERVICE FOR PARTS, SERVICE, OR TECHNICAL INFORMATION CONTACT: POUR DES PIÈCES, SERVICE OU CONTACT DE L'INFORMATION TECHNIQUE : USA / CANADA: JEDMED Instrument Company 5416 JEDMED CT. St. Louis, MO 63129 Phone 314-845-3770 314-845-3771...
  • Page 25 ELECTRICAL COMPONENTS - PHOENIX III - 115V / 230V WITHOUT FOOT CONTROL OPTION SWITCH PAD LINAK JUNCTION BOX HAND CONTROL SWITCH HARNESS BASE ACTUATOR STRAIGHT CABLE LINAK HAND CONTROL CONTROL BOX CABLE POWER CABLE A/ C INLET HARNESS LOCK CLIP...
  • Page 26 ELECTRICAL COMPONENTS - PHOENIX III - 115V / 230V WITH FOOT CONTROL OPTION SWITCH PAD LINAK HAND CONTROL JUNCTION BOX SWITCH HARNESS BASE ACTUATOR LINAK CONTROL BOX OPTIONAL TEE CABLE FOOT/ HAND CONTROL CABLE POWER CABLE OPTIONAL A/ C INLET...
  • Page 27 ELECTRICAL DIAGRAM - E5550/E4550 - 115V OPTIONAL TEE CABLE (FOOT CONTROL) OPTIONAL COILED CABLE SW18 (FOOT CONTROL) 1234 OPTIONAL FOOT CONTROL REV. F, 12/05/14...
  • Page 28 ELECTRICAL DIAGRAM - PHOENIX III - 230V OPTIONAL TEE CABLE (FOOT CONTROL) OPTIONAL SW18 COILED CABLE (FOOT CONTROL) OPTIONAL 1234 FOOT CONTROL REV. F, 12/05/14...
  • Page 29 ELECTRICAL PART NUMBERS - PHOENIX III - 115V / 230V 10-4580 LINAK CB6 CONTROL (115V) 10-4581 LINAK CB6 CONTROL (230V) 10-2250 SWITCH, CIRCUIT BREAKER, 5A 15-1190 ELECTRIC DISTRIBUTION BOX (115V) 15-1191 ELECTRIC DISTRIBUTION BOX (230V) 10-4546 LINAK DJB MODULE 15-1195...
  • Page 30 PARTS BREAKDOWN: PHOENIX III CHAIR FRAME ASSEMBLY DETAIL B SCALE 1 : 4 LIGHTLY GREASE (62-1720) ON MOVING MATING SURFACES LIGHTLY GREASE (62-1720) ON MOVING MATING SURFACES DETAIL A SCALE 1 : 4 35 39 24 25 WIRE TROUGH AND SUPPORT...
  • Page 31 PARTS BREAKDOWN: PHOENIX III CHAIR FRAME ASSEMBLY 60 48 60 48 41 23 38 37 35 39 35 39 ELECTRICAL COMPONENT LAYOUT REV. F, 12/05/14...
  • Page 32: Parts Listing / Frame

    PARTS LISTING: FRAME ASSEMBLY PHOENIX III MODEL ITEM PART NO DESCRIPTION 95-1425 ASSEMBLY: HEAD REST RELEASE MECHANISM 15-1172 HARNESS: BACK, ENT 91-2795 BEZEL: HAND CONTROL 15-1170 CONTROL SWITCH: BACK COVER 50-2700 BACK COVER 91-2779 TROUGH, WIRE GUIDE 91-2321 LINK: SYNCH LEG...
  • Page 33 PARTS BREAKDOWN: PHOENIX III CHAIR BASE ASSEMBLY DETAIL A SCALE 1 : 4 39 62 34 73 89 87 37 90 17 67 11 46 71 51 62 57 39 66 60 54 84 86 85 REV. F, 12/05/14...
  • Page 34: Parts Listing / Base

    PARTS LISTING: BASE ASSEMBLY PHOENIX III MODEL ITEM ITEM NO. QTY PART NO DESCRIPTION NO. QTY PART NO DESCRIPTION 91-2752 FLOOR PLATE 59-1880 HEX 5/ 8-18 UNF-2A X 2 1/ 2, GR8 91-2756 BOTTOM PLATE: SWIVEL 59-1985 SHOULDER: 1/ 4 X 3/ 8, SST...
  • Page 35 PARTS BREAKDOWN / LISTING: ARM ASSEMBLY PHOENIX III MODEL 59-3860 BUT HD SOC # 8-32 UNC X 3/ 4, SS 90-2327 DISC FOR SEAT HINGE/ BLK DELRIN 90-2328 DISC, BLACK DELRIN; ARM OPTION 91-2801R WELDMENT: ARMREST, RH 91-2801L WELDMENT: ARMREST, LH 60-1571 SPRING: COMP, .343 X 1.25 X .035...
  • Page 36 PARTS BREAKDOWN: PHOENIX III UPHOLSTERY PACKAGES INSTALLATION INSTRUCTIONS -WARNING- ALWAYS INSURE THAT UPHOLSTERY IS CORRECTLY / SECURELY ATTACHED TO THE CHAIR FRAME BEFORE USE. AVERTISSEMENT Il faut toujours vérifier pour s'assurer que la sellerie est correctement et solidement fixé au châssis chaise.
  • Page 37 PHOENIX III UPHOLSTERY KIT P/N 100-4450U NOTES: UPHOLSTERY: HEADREST, ENT (ITEM 1) 67-1340U IS INTERCHANGEABLE WITH 67-1361U. ARM PADS NOT INCLUDE IN PACKAGE, ARM PAD P/ N K905013. 67-4451 UPHOLSTERY; LEG SUPPORT 67-3011 UPHOLSTERY: SEAT 67-4450 UPHOLSTERY: BACK 67-1360U UPHOLSTERY: HEADREST ITEM QTY.
  • Page 38: Swivel Brake Adjustment

    SWIVEL BRAKE ADJUSTMENT PHOENIX III MODEL USE A NO. 2 PHILLIPS SCREW DRIVER TO TIGHTEN THE TWO ADJUSTMENT SCREWS. ADJUSTMENT SCREWS CAN BE ACCESSED THROUGH OPENINGS IN THE BASE COVER. MAKE ADJUSTMENTS WITH THE BRAKE IN THE RELEASED MODE. TIGHTEN EACH SCREW 1/8 TURN CLOCKWISE TO INCREASE BRAKE HOLDING ACTION.
  • Page 39: Trouble Shooting

    ALSO CHECK THE CABLES TO AND FROM THE DJB BOX TO BE SURE THAT THEY ARE PLUGGED IN TIGHTLY. (PAGE 24 ITEM 4) RESET CONTROL BOX- FOR PROGRAMMABLE MODEL PHOENIX III. PRESS AND HOLD BOTH POSITION ‘1’ & POSITION ‘2’ SWITCHES DOWN UNTIL BEEPING STOPS.
  • Page 40 Guidance and manufacturer’s declaration – electromagnetic immunity The JEDMED model PHOENIX III Chair is intended for use in the electromagnetic environment specified below. The customer or the user of the JEDMED model PHOENIX III should assure that they are used in such an environment.
  • Page 41 Guidance and manufacturer’s declaration – electromagnetic immunity The JEDMED model PHONEX III is intended for use in the electromagnetic environment specified below. The customer or the user of the JEDMED model PHONEX III should assure that they are used in such an environment.
  • Page 42: Separation Distances

    Guidance and manufacturer’s declaration – electromagnetic emissions The JEDMED model PHONEX III is intended for use in the electromagnetic environment specified below. The customer or the user of the JEDMED model PHONEX III should assure that they are used in such an environment.
  • Page 43 JEDMED Instrument Company 5416 Jedmed CT. St. Louis, MO 63129-2217 Phone 314-845-3770 Fax 314-845-3771 REV. F, 12/05/14...