Dry Mode - Gree FGR20/BNa-M Service Manual

Duct type split air conditioner
Table of Contents

Advertisement

Duct Type Split Air Conditioner
Service Manual
When Tambient ≥ Tset+1℃ , the unit will run in cooling mode. In this case, compressor and outdoor fan run;
Indoor fan runs at setting speed.
When Tambient ≤ Tset-1℃ , the unit will stop running in cooling mode. In this case, compressor and outdoor
fan stop running; Indoor fan runs at setting speed.
When Tset -1℃< Tambient ≤ Tset+1℃ ,the unit will keep its previous running state.

2.7 Dry mode

Normally on mode during dry operation
Start for 6min and stop for 4min during dry operation
CONTROL
16
Control object
ON
Compressor
ON
Outdoor fan
ON
Indoor fan
360s
Control object
OFF
Compressor
OFF
Outdoor fan
OFF
Indoor fan
180s
Control object
ON
Compressor
ON
Outdoor fan
ON
Indoor fan
10s
360s
Fan mode
OFF
High speed
OFF
V(set)
10s
Vset
High speed
5s
ON
OFF
ON
OFF
5s
10s
240s
360s
ON
Time
ON
ON
ON
Time
ON
OFF
ON
OFF
Time
5s
240s

Hide quick links: