Delta DX-2100 Series User Manual page 72

Industrial 3g cloud router
Hide thumbs Also See for DX-2100 Series:
Table of Contents

Advertisement

several alarm criteria. For example, the formula can be: {$2048}>100
Event Interval
The time interval of alarm sending
Repeat Times
The repeated times of alarm sending
Alarm Status
Enable or disable this alarm setting
Alarm Content
Set up the information shown on the alarm contents. The content of the alarm
will be sent to the target when alarm criteria are met. The information order can
be self-defined.
Time: the time when the alarm occurred
Date: the date when the alarm occurred
Name: the name of the occurred alarm
Description: the description of the occurred alarm
For example: Register $2048 represents electrical voltage, the value of register
$2048 is 10, and the alarm content is set as: {Date} {Time} Voltage = {$2048},
then the alarm content received by users will be: 2016/06/01 10:00:00(currently
time) Voltage = 10. The maximum content length is 160 characters.
Target Receiver
Set up the recipient. User can maintain the list by 【Control List Of Event
Management】in Privilege Management function.
SMS Queries Event: user can declar a query event, when the mobile number in the Control List of event send a
query message, system will reply the special content to the mobile number.
Description
Cha p ter 3 In tr od ucti on to F unc tio ns
Default
0
0
Enable
N/A
N/A
_3
3 - 4 9