General Information

This guide covers the installation of the HUBBCOM Remote Station, Model GRC600. The Model GRC600
Remote Station is designed for access control See the GAI-Tronics website at
system specifications, warranty information, and the GUDA (GAI-Tronics Universal Device Application).

Important Safety Instructions

Read, follow, and retain instructions—All safety and operating instructions should be read and followed
before operating the unit. Retain instructions for future reference.
Heed warnings—Adhere to all warnings on the unit and in the operating instructions.
Attachments—Attachments not recommended by the product manufacturer should not be used, as they may
cause hazards.
Servicing—Do not attempt to service this unit by yourself. Opening or removing covers may expose you to
dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
Changes or Modifications Not Expressly Approved By GAI-Tronics For Compliance Could Void The
User's Authority To Operate The Equipment.
ATTENTION
national, and international electrical codes. North America - Consult the National Electrical Code (NFPA 70),
Canadian Standards Association (CSA 22.1), and local codes for specific requirements regarding your installation.
Class 2 circuit wiring must be performed in accordance with the NEC.
These enclosures must be installed by trained, qualified and competent personnel. Installation must comply with
state and national regulations, as well as safety practices for this type of equipment.
WARNING
—Use only 24 V dc power supplies that conform to UL/CSA/CE Class II, Double Insulated
Onderhoud—Probeer dit apparaat niet zelf te repareren. Het openen of verwijderen van afdekkingen kan u
blootstellen aan gevaarlijke spanning of andere gevaren. Laat alle onderhoud over aan bevoegd
onderhoudspersoneel.
HUBBCOM Smart Controllers zijn alleen bedoeld voor gebruik binnenshuis.
AANDACHT
—Gebruik alleen 24 VDC-voedingen die voldoen aan UL / CSA / CE Klasse II, dubbel
Dépannage—N'essayez pas de réparer cet appareil vous-même. Ouvrir ou retirer les capots peut vous exposer à
des tensions dangereuses ou à d'autres dangers. Confiez toute réparation à un personnel qualifié.
Les contrôleurs intelligents HUBBCOM sont conçus pour une utilisation en intérieur uniquement.
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
V
ISIT WWW
G A I - T R O N I C S
A H U B B E L L C O M P A N Y
Quick Installation Guide
—Install equipment without modification and according to all applicable local,
supplies with over voltage and short circuit protection. Use only a dc source with a 50-
watt maximum output or fuse the supply with a 2-amp fuse. EMI standards to Class B.
geïsoleerde voedingen met overspanning en kortsluitbeveiliging. Gebruik alleen een
DC-bron met een maximale output van 50 W of fuseer de voeding met een 2-ampère
zekering. EMI-normen voor klasse B.
610-777-1374 ◼ 800-492-1212 ◼ Fax: 610-796-5954
.
-
.
GAI
TRONICS
COM FOR PRODUCT LITERATURE AND MANUALS
®
https://www.gai-tronics.com
Pub. 42004-538AQG
for

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAI-TRONICS HUBBCOM GRC600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hubbell GAI-TRONICS HUBBCOM GRC600

  • Page 1 Pub. 42004-538AQG G A I - T R O N I C S ® A H U B B E L L C O M P A N Y HUBBCOM GRC600 Remote Station Quick Installation Guide General Information This guide covers the installation of the HUBBCOM Remote Station, Model GRC600. The Model GRC600 Remote Station is designed for access control See the GAI-Tronics website at https://www.gai-tronics.com system specifications, warranty information, and the GUDA (GAI-Tronics Universal Device Application).
  • Page 2 Pub. 42004-538AQG HUBBCOM GRC600 Remote Station Quick Installation Guide Page 2 of 5 ATTENTION —Utilisez uniquement des alimentations 24 Vcc conformes à UL / CSA / CE Classe II, des alimentations à double isolation avec protection contre les surtensions et les courts- circuits.
  • Page 3 Pub. 42004-538AQG HUBBCOM GRC600 Remote Station Quick Installation Guide Page 3 of 5 Assemble the front cover to the mounting plate and secure with the two security screws removed from the bottom of the station in Step 2. Tighten the screws to 3–5 in∙lb. Wiring HUBBCOM Remote stations are equipped with screw connection terminal blocks that accept 26–16 AWG wires.
  • Page 4 Pub. 42004-538AQG HUBBCOM GRC600 Remote Station Quick Installation Guide Page 4 of 5 Table 3. Purpose Term Block-Pin Label Output TB3-1 Output TB3-2 USB1 & USB2 Complete the following steps to terminate the USB connections at terminal blocks TB4 and TB5: Install appropriately sized ferrules onto the wire ends.
  • Page 5 Pub. 42004-538AQG HUBBCOM GRC600 Remote Station Quick Installation Guide Page 5 of 5 Table 5. Input Terminations at Terminal Block TB6 Purpose Term Block-Pin Label TB6-1 TB6-2 TB6-3 TB6-4 TB6-5 TB6-6 TB6-7 TB6-8 TB6-9 TB6-10 Service and Spare Parts Contact a regional service center for assistance if the equipment requires service or spare parts. An RA# ( return authorization number) will be issued if service is required.

Table of Contents