HUBBCOM™ Remote GRC600 Station

General Information

This guide covers the installation of the HUBBCOM Model
GRC600 Remote Station. The Model GRC600 Remote
Station is designed for use as an access control device and/or
a remote audio/video monitoring station. It can function in a
standalone configuration or as part of a HUBBCOM system.
See the GAI-Tronics website at
for system specifications, warranty information, and the
GUDA (GAI-Tronics Universal Device Application).

Important Safety Instructions

Read, follow, and retain instructions—All safety and
operating instructions should be read and followed
before operating the unit. Retain instructions for future
reference.
Heed warnings—Adhere to all warnings on the unit and
in the operating instructions.
Attachments—Attachments not recommended by the
product manufacturer should not be used, as they may
cause hazards.
Servicing—Do not attempt to service this unit by
yourself. Opening or removing covers may expose you
to dangerous voltage or other hazards. Refer all
servicing to qualified service personnel.
HUBBCOM Smart Controllers are designed for indoor
use only.
ATTENTION
These enclosures must be installed by trained, qualified and competent personnel. Installation must comply with state and
national regulations, as well as safety practices for this type of equipment.
WARNING
—Use only 12 or 24 V dc power supplies that conform to UL/CSA/CE Class II, Double Insulated
Onderhoud—Probeer dit apparaat niet zelf te repareren. Het openen of verwijderen van afdekkingen kan u blootstellen
aan gevaarlijke spanning of andere gevaren. Laat alle onderhoud over aan bevoegd onderhoudspersoneel.
HUBBCOM Smart Controllers zijn alleen bedoeld voor gebruik binnenshuis.
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
V
G A I - T R O N I C S
A H U B B E L L C O M P A N Y
Quick Installation Guide
https://www.gai-tronics.com
—Install equipment without modification and according to all applicable local, national, and
international electrical codes. North America - Consult the National Electrical Code (NFPA
70), Canadian Standards Association (CSA 22.1), and local codes for specific requirements
regarding your installation. Class 2 circuit wiring must be performed in accordance with the
NEC.
supplies with over voltage and short circuit protection. Use only a dc source with a 50-watt
maximum output or fuse the supply with a 2-amp fuse. EMI standards to Class B.
610-777-1374  800-492-1212  Fax: 610-796-5954
.
-
.
ISIT WWW
GAI
TRONICS
COM FOR PRODUCT LITERATURE AND MANUALS
®
Figure 1. HUBBCOM Remote Station
Pub. 42004-538AQG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAI-TRONICS HUBBCOM GRC600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hubbell GAI-TRONICS HUBBCOM GRC600

  • Page 1: General Information

    Pub. 42004-538AQG G A I - T R O N I C S ® A H U B B E L L C O M P A N Y HUBBCOM™ Remote GRC600 Station Quick Installation Guide General Information This guide covers the installation of the HUBBCOM Model GRC600 Remote Station.
  • Page 2 Pub. 42004-538AQG HUBBCOM™ Remote GRC600 Station Quick Installation Guide Page 2 of 6 AANDACHT —Gebruik alleen 12 oder 24 VDC-voedingen die voldoen aan UL/CSA/CE Klasse II, dubbel geïsoleerde voedingen met overspanning en kortsluitbeveiliging. Gebruik alleen een DC-bron met een maximale output van 50 W of fuseer de voeding met een 2-ampère zekering. EMI- normen voor klasse B.
  • Page 3 Pub. 42004-538AQG HUBBCOM™ Remote GRC600 Station Quick Installation Guide Page 3 of 6 5. Assemble the front cover to the mounting plate and secure it with the two included security screws. 6. Tighten the screws to 3–5 in∙lb. Mounting on a Weatherproof Two-Gang Electrical Box (Exterior Installations) : The HUBBCOM Remote Station is mounted on a (customer supplied) weatherproof metallic two-gang electrical box.
  • Page 4 Pub. 42004-538AQG HUBBCOM™ Remote GRC600 Station Quick Installation Guide Page 4 of 6 Local Power (Optional) Table 1. Optional Local Power Termination Terminal Block TB2 Terminate the input power cable at terminal block TB2 if PoE (power over Ethernet) is not available: Purpose Term Block-Pin Label...
  • Page 5: Specifications

    Pub. 42004-538AQG HUBBCOM™ Remote GRC600 Station Quick Installation Guide Page 5 of 6 Specifications Electrical Power Consumption Network Power ............................ PoE/PoE+, IEEE 802.23af Local Power ..............................12–24 V dc, 10 W Ethernet Cable ................................Category 5e or better Speed .................................. up to 1000 Mbps USB (Quantity 2) Cable ....................................
  • Page 6 Pub. 42004-538AQG HUBBCOM™ Remote GRC600 Station Quick Installation Guide Page 6 of 6 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 7 Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document.

Table of Contents