TABLE OF CONTENTS
Technical data for Jøtul F 320 ................................................. 9
General safety precautions ....................................................... 9
Measures to prevent fires ......................................................... 9
Foundations ................................................................................. 9
Chimney ........................................................................................ 9
Air circulation ................................................................................ 9
Assembly prior to installation ................................................. 10
Control of functions ................................................................... 10
Installation of flue pipe ............................................................. 10
Connection to chimney ............................................................. 10
Initial lighting and daily use .................................................... 10
Initial lighting ............................................................................... 10
Daily use ........................................................................................ 10
Cleaning the glass ....................................................................... 11
Ash removal .................................................................................. 11
Cleaning and soot removal ...................................................... 11
Sweeping of flue pipes to the chimney ............................... 11
Control of the stove ................................................................... 11
External maintenance ................................................................ 11
The length, quantity and quality of logs ............................. 11
Jøtuls definition of quality wood .......................................... 12
Service
Changing the burn plates ......................................................... 12
Changing the air chamber ........................................................ 12
Changing the baffle plate ......................................................... 12
Changing the heat shield and side plates ........................... 12
Changing the lower front plate .............................................. 12
Adapted decorations in soapstone ........................................ 13
Grilling grid ................................................................................... 13
Flue pipe decoration .................................................................. 13
8
Relationship to the
authorities in various
countries
The Jøtul F 320 is a clean burning free-standing heating
stove for solid fuel.
The product data plate is located on the heat shield and is
made of heat-resistant material. The following information
is listed on the data plate: Manufacturer and address,
model number, manufacturing number, rated heat output,
registration number (after assignment), style, and safety
measurements.
Prior to starting on the installation the appropriate permits
must be obtained from the relevant local authorities.
Installation of a fireplace must be according to local codes
and regulations in each country. Your dealer has been
specially selected for his knowledge of your local codes
and may provide assistance in ensuring that your
installation is safe and legal.
Instructions for mounting, installation and use are enclosed
with the product. The installation may only be used when
it has been inspected and a certificate of completion has
been issued.
Warning! Please ensure that there is adequate ventilation
in the room in which the stove is to be installed.
Insufficient ventilation may cause oxygen depletion in the
room and may lead to tiredness, nausea and sickness, and is
very dangerous.
Special attention must be paid to the following:
The chimney or flue system must comply with the Building
Regulations for heat producing appliances. It is important
to ensure that the chimney has the correct dimensions for
the stove and that the attachment to the chimney is sealed
and is functioning properly. Smoke gas entering enclosed
spaces may represent a serious health risk.
The chimney or flue must be sound and clean. If it has been
used with a wood, coal or other solid fuel fire, it must be
swept before the stove is installed.
Ensure that only one stove is served by the chimney or flue
system.
Ensure that the chimney or flue is structurally sound. In
particular, it must not be possible for products of
combustion to come into contact with combustible
materials in the structure of the building.
In some situations it may be advisable to fit a flue liner
prior to the installation of the stove. Your installer will advise
if this is necessary.