Clearance To Combustibles For Space Heating And Brooder Installation; Figure 4. Standard Reflector; Figure 5. One Side Reflector - Calcana SR Series Specifications, Installation, Operation Service And Spare Parts Manual

Table of Contents

Advertisement

SR-SERIES
6.1

CLEARANCE TO COMBUSTIBLES FOR SPACE HEATING AND BROODER INSTALLATION

WARNING: I
n all situations, clearances to combustibles must be maintained. Minimum clearance
from heater must be maintained from vehicles parked below heater. The posting of signs may be
required in storage areas referring to clearances to combustibles to the heater and/or limiting the
stacking height of stored Items near the heater specifying a maximum height. Clearances are not for use
in four (4) sided enclosures. Certain materials or items, when stored under the heater, will be subjected
to radiant heat and could be seriously damaged.
WARNING
: The stated clearance to combustibles represents a surface temperature of 90°F (32°C)
above room temperature. Building material with low heat tolerance (such as plastics, vinyl siding, canvas,
tri-ply, etc...) may be subject to degradation at lower temperatures. It is the installer's responsibility to
assure that adjacent materials are protected from degradation. When in doubt, check heat tolerance of
building material(s) with their manufacturer.
A
B
INSTALLATION TYPE 1 - (inches) (cm)
Input*
A
B
40
6" (16cm)
12" (31cm)
50
6" (16cm)
12" (31cm)
60
15" (39cm)
6" (16cm)
75
20" (51cm)
6" (16cm)
80
6" (16cm)
20" (51cm)
100
6" (16cm)
22" (56cm)
125
6" (16cm)
22" (56cm)
150
6" (16cm)
24" (70cm)
175
6" (16cm)
24" (70cm)
175+20'
6" (16cm)
20" (51cm)
**
200
6" (16cm)
27" (69cm)
225
200
225+20'
6" (16cm)
20" (51cm)
**

Figure 4. STANDARD REFLECTOR

D
C
C
D
36" (92cm)
12" (31cm)
36" (92cm)
12" (31cm)
44" (112cm)
15" (39cm)
50" (127cm)
20" (51cm)
53" (135cm)
20" (51cm)
55" (140cm)
22" (56cm)
55" (140cm)
22" (56cm)
60" (152cm)
24" (70cm)
65" (152cm)
24" (70cm)
45" (115cm)
20" (51cm)
65" (165cm)
27" (69cm)
45" (115cm)
20" (51cm)
* per 1,000 Btu/hr input
INSTALLATION TYPE 2 – (inches) (cm)
Input*
A
40
6" (16cm)
50
6" (16cm)
60
6" (16cm)
75
6" (16cm)
80
6" (16cm)
100
6" (16cm)
125
6" (16cm)
150
6" (16cm)
175
6" (16cm)
175+20'
6" (16cm)
**
200
6" (16cm)
225
200
225+20'
6" (16cm)
**

Figure 5. ONE SIDE REFLECTOR

** Clearance 20' (6.1m) downstream from burner
9
B
C
12" (31cm)
36" (92 cm)
36" (92 cm)
12" (31cm)
36" (92 cm)
36" (92 cm)
44" (112cm)
12" (31cm)
36" (92 cm))
50" (127cm)
12" (31cm)
36" (92 cm)
20" (51cm)
53" (135cm)
40" (102cm)
22" (56cm)
55" (140cm)
40" (102cm)
22" (56cm)
55" (140cm)
40" (102cm)
24" (70cm)
60" (152cm)
40" (102cm)
24" (70cm)
65" (165cm)
40" (102cm)
16" (41cm)
45" (115cm)
36" (92 cm)
27" (69cm)
65" (165cm)
40" (102cm)
16" (41cm))
45" (115cm)
36" (92 cm)
D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents