function, then press Trigger (10) to confirm. Use the arrows to change the value. Press the
Trigger to save and Mode to return to normal functioning.
E
HAL
LAL
Power off
Backlight
Set time
Time
stamp
Selectable 5 levels of brightness.
Erase file
Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS (hour/minute
Turn on Time stamp to save thermal images with real-time stamp.
Save
Turn off Time stamp to hide date and time on stored thermal images.
mode
Select Yes, All image! to clear all stored thermal images.
Noise filter
Select Reset to recover the factory setting data.
Select Use Median Value to reduce noise in an image.
Select No Filter to display real image noise.
STORAGE & CLEANING
The thermal imaging camera should be stored at room temperature. The sensor lens is
the most delicate part of the thermometer. The lens should be kept clean at all times, care
should be taken when cleaning the lens using only a soft cloth or cotton swab with water
or medical alcohol. Allowing the lens to fully dry before using the thermometer. Do not
submerge any part of the thermometer.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
'Battery OK': measurements
'Battery Low': battery needs to be
"Battery OK":
are possible
replaced, measurements are still possible
Measurements are
When the 'Low Battery' icon indicates the battery is low, the battery should be replaced immediately w
possible
Please note: It is important to turn the instrument off before replacing the battery otherwise the therm
• When the 'Low Battery' icon indicates the battery is low, the battery should be replaced
Dispose of used battery promptly and keep away from children.
immediately with 4 AA, 1.5V batteries.
• Please Note: It is important to turn the instrument off before replacing the battery
otherwise the thermometer may malfunction
• Dispose of used batteries properly and keep away from children.
32*31
-20~250°C (-4~482°F)
SPECIFICATIONS:
2% of reading, or 2°C(4°F) whichever is greater
Thermal Image Resolution:
0.1°C
Measurement Range:
Accuracy(Tamb=20~26°C):
9Hz
Thermal Sensitivity:
40*40 deg
Frame Rate:
0.95 default – adjustable 0.1 to 1 step .01
Field of View:
Focus free
Emissivity Range:
2.8
Focus:
LCD (inch):
Color
LCD type:
Stores up to 60000 images/GB,
Image Storage:
Support 8G micro SD card
Memory Type:
8~14um
Spectral Range:
USB
Interface:
AA*4
Battery Type:
Battery Life (with backlight):
6
Dimensions:
94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch)
Weight:
411 grams(14.5 oz) including batteries (AA*4pcs)
EMC/RFI: Readings may be affected if the unit is operated within radio frequency electromagnetic field strength
EMC/CRFI: Reading may be affected if the unit is operated within radio frequency elec-
meter, but the performance of the instrument will not be permanently affected.
tromagnetic field strength of approximately 3 volts per meter, but the performance of the
instrument will not be permanently affected.
4
The default emissivity is 0.95, or select other default emissivity: Matt:
0.95, Semi-matt: 0.8, Semi-glossy: 0.6, Glossy: 0.3
Select Set Value to adjust the emissivity (0.1 to 1, in 0.01 steps)
You can select HAL or LAL to adjust the High Alarm ( HAL) or Low Alarm
(LAL) limits.
The default setting is "Auto off 1 min", you can select other default values:
5, 10, 20 minutes or "No auto off". Manually power off the device by
pressing Mode Key (2) for 3 seconds.
Select low, middle or high
Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS
(hour/minute/second) formats.
Turn on Time Stamp to save thermal images with time stamp.
Turn off Time Stamp to hide date and time on stored thermal images.
Select All picture! to clear all stored thermal images.
Select All movie! to clear all stored videos.
Select Picture to save thermal images in image mode. (BMP and Excel
formats)
Select Movie to save thermal images in video mode.
Turn on Filter to reduce noise in an image.
Turn off Filter to display real image noise.
'Battery Low': battery needs to be
"Battery Low":
replaced, measurements are still possible
Battery needs to be replaced,
measurements are still possible
32*31
32*31
-20~250°C (-4~482°F)
-20~250°C (-4~482°F)
2% of reading, or 2°C(4°F) whichever is greater
2% of reading, or 2°C(4°F) whichever is greater
0.1°C
0.1°C
9Hz
9Hz
40*40 deg
40*40 deg
0.95 default – adjustable 0.1 to 1 step .01
0.95 default – adjustable 0.1 to 1 step .01
Focus free
Focus free
2.8
2.8
Color
Color
Stores up to 60000 images/GB,
Stores up to 60000 images/GB,
Bitmap (BMP) file format.
Support 8G micro SD card
Support 8G micro SD card
8~14um
8~14um
USB
USB
AA*4
AA*4
6
6
94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch)
94.65 x 74.03 x 233.68mm (3.73 x 2.91 x 9.20 inch)
411 grams(14.5 oz) including batteries (AA*4pcs)
411 grams(14.5 oz) including batteries (AA*4pcs)
'Battery Low': battery needs to be
replaced, measurements are still possible
32 x 31
-20 to 250°C(4°F) whichever is greater
±2% of reading, or 2°C (4°F) whichever is greater
0.1°C
9Hz
40 x 40 deg
0.95 default - adjustable 0.1 to 1 (in 0.01 steps)
Focus free
2.8
Color
Bitmap (BMP) file format.
Store up to 25000 images/GB, BMP format.
Support 8G micro SD card
8.14um
USB
AA*4
6 hrs continuous use
94.65 x 74.03 x 233.68 mm (3.73 x 2.91 x 9x20 inch)
390 grams (13.8 oz) Including batteries (AA*4pcs)
www.mastercool.com
'Battery Exhausted': measurem
'Battery Exhausted': measurements are
"Battery Exhausted:
not possible
Measurements are not
possible
Bitmap (BMP) file format.
'Battery Exhaus
not possible
n

Advertisement