1.0 Introduction
The 3M
Fiber Dome Terminal Closure FDTC 08S
(Direct Splice) or 3M
Fiber Dome Closure FDC 08S-A
can accommodate up to eight 0.47" (12 mm) cables when
using the 3 mm external cable assembly module (ECAM)
and two 0.79" (20 mm) main cables. The 3M
Cable Assembly Module (ECAM) Cable Entry Port Kit is
designed to accept fiber optic loose tube and central tube
cables with external diameters from 0.16" to 0.47" (4–12
mm) and flat drop 0.18" x 0.32". It will accommodate
cables with single or dual cable strength members. The
FDTC 08S direct splice can accommodate both dielectric
and armored drops and cables. For armored cables, the
grounding kit must be purchased separately.
Specifications
Item
Qty.
Tray Capacity
4
Splice Tray Capacity
24
72
12
Max Drops/Branch Cables
8
Main Cables
2
Ground Lugs
0 or 1
Air Valve
Express Storage
June 2012
78-8135-6188-9-D
External
Description
3M
Fiber Optic Splice Trays
2538
Single Fusion (Double Stacked)
Mass Fusion
3M
Fibrlok
Splices
0.16" (4 mm) min to 0.47"
(12 mm) max diameter
0.39" (10 mm) min to 0.79"
(20 mm) max diameter
5.8 PSI (40 kPa) max flash
72" (1.8 m) max of LBT 72F
(12 fibers/buffer)/RF 144F
2.0 Kit Contents
A. Dome
B. Band
C. Storage tray
D. Base assembly
E. 3M
Double Cable Entry Port External Cable
Assembly Module ECAM-20MM-D
F.
Double Cable Entry Port ECAM-20MM-D loose
parts
G. (1) 3M
Fiber Optic Splice Tray
2538-24-DF/72-MF
H. Double Cable Entry Port ECAM-20MM-D
Instructions
I.
Fiber Dome Terminal Closure FDTC 08S and
Fiber Dome Closure FDC 08S-A Instructions
A
F
B
C
D
E
G
3

Advertisement

loading

Summary of Contents for 3M FDTC 08S

  • Page 1 0.47" (12 mm) cables when C. Storage tray using the 3 mm external cable assembly module (ECAM) D. Base assembly and two 0.79" (20 mm) main cables. The 3M ™ External Cable Assembly Module (ECAM) Cable Entry Port Kit is E.
  • Page 2 1-800-426-8688 for a replacement product. Using cable ties, secure the central tube in the 3.0 3M Fiber Dome Terminal Closure ™ storage tray as shown. FDTC 08S (Direct Splice) and Fiber Dome Closure FDC ™ 08S-A Base Configuration Ground Stud 1/4-20 Thread...
  • Page 3: Cable Splicing

    Discrete Fusion 2521-F ™ Place splice tray in storage tray. Tabs on tray nest between tabs in storage tray. ™ 2521-FL Mass Fusion and 3M ™ Fibrlok ™ Splices Install splice insert into splice tray by slipping tabs under metal retainers as shown.
  • Page 4 6.6.2 Route fiber into splice tray to determine 6.6.5 Up to four 3M Fiber Optic Splice Trays ™ amount of buffer tube to remove. Remove 2538 can be stacked in closure. buffer tube and clean fiber as required. Ribbon 6.6.3 Cut a one-inch (25 mm) long section of 6.7.1 Recommend ribbon splicing be done...
  • Page 5 At the same time pull ring outward. Drops number one to four can be routed as shown. Lightly lube both the O-ring seal area base port and the 3M External Cable Assembly ™ Module (ECAM) Port O-ring using the supplied lubricant.
  • Page 6 8.0 Closure Sealing To add drop number five through eight temporarily place the splice tray into the storage tray and route remaining drop(s) as shown. Ensure both the dome seal area and base O-ring Mark tray entry point on buffer tubes. is free of dirt or any damage.
  • Page 7 9.0 3M Fiber Dome Terminal FDT08 ™ Fully close latch to seat dome onto the base. Accessories Product Number 3M ID Description ECAM-12MM 80-6113-1696-1 12MM ECAM CABLE ENTRY PORT 20MM DOUBLE CABLE ENTRY ECAM-20MM-D 80-6113-2951-9 PORT, US ECAM (18, 20, 27MM) CABLE GND...
  • Page 8 Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

This manual is also suitable for:

Fdc 08s-a