A.2 Operating Temperature Limitations
Table A-2 Operating temperature limitations
Configuratio
n
8 x 2.5" SAS/
SATA drive
configuration
Issue 03 (2020-04-20)
Description
Year and month (two characters).
● The first character indicates the year.
– Digits 1 to 9 indicate years 2001 to 2009, respectively.
– Letters A to H indicate years 2010 to 2017, respectively.
– Letters J to N indicate years 2018 to 2022, respectively.
– Letters P to Y indicate years 2023 to 2032, respectively.
NOTE
The years from 2010 are represented by uppercase letters excluding
I, O, and Z because the three letters are similar to digits 1, 0, and 2.
● The second character indicates the month.
– Digits 1 to 9 indicate January to September, respectively.
– Letters A to C indicate October to December, respectively.
Sequence number (six characters).
RoHS compliance (one character). Y indicates RoHS compliant.
Internal model, that is, product name.
Max. 30°C
(86°F)
● All options
supported
Copyright © Huawei Technologies Co., Ltd.
Max. 35°C
Max. 40°C
(95°F)
(104°F)
● All options
● Options
supported
supported:
processors
of up to
165 W
● Options
not
supported:
GPU cards
A Appendix
Max. 45°C
(113°F)
● Options
supported:
processors
of up to
140 W
● Options
not
supported:
– PCIe
SSD
cards
– NVMe
drives
– GPU
cards