Specification - Wolf ZP-3 Installation Instructions Manual

Freshwater module/ dhw circulation pump set
Table of Contents

Advertisement

Available languages

Available languages

Weight
Connections
Main components
Dimensions (HxWxD)
DHW output
Adjustable DHW temperature range
Plate heat exchanger
Thermal insulation
Min. permiss. operating temp.
Max. permiss. operating temp.
Max. permiss. operating pressure
Charging pump:
DHW circulation pump (optional):
Mixing valve
10/45 °C cold water/DHW temperature and a buffer flow temperature of 65 °C; for further operating points see sizing diagram
1)
46

Specification

E
4
8
F
9
approx. 20 kg
A = cold water IN, 1" female thread
B = DHW OUT, 1" female thread
C = from buffer, 1" male thread
D = to buffer, 1" male thread
E = DHW circulation line (not part of the standard delivery)
F = flushing connection, ¾" male thread
1 = plate heat exchanger
2 = bypass pipe for admixing from centre zone
3 = push-fit connection for DHW circulation unit
4 = primary pump Yonos PARA HU 25/7.0 PWM 1W
5 = PT1000 temperature sensor
6 = mixing valve with servomotor
7 = freshwater module controller
8 = DHW sensor
9 = optimum DHW circulation unit with pump and electronic return thermostat (for
pulsed or timed operation)
600 x 400 x 305
2 - 40 l/min DHW
1)
40 ... 65 °C
41 plates; material: stainless steel 1.4404; copper-brazed
EPP
2 °C
95 °C
Cold water/DHW 10 bar; heating 3 bar
Yonos PARA HU 25/7.0 PWM 1W
230 V/50 Hz
Speed = 800 - 4660 rpm
Power consumption: 3 - 45 W
Rated current = 0.03 - 0.44 A
Max. head 286 mbar
E3-00-3/000 BRU
230 V/50 Hz
Speed = 4800 rpm
Max. power consumption: 27.3 W (+ clock 1.5 W)
Controller thermostat range = 20 ... 70 °C
ESBE SLB239
Power supply 12 V DC
Power consumption: 0.6 W
Rated current: 0.5 A
A D
B
5
C
F
3
2
6
7
1
3065014_201612

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fws-2-80

Table of Contents