Onyx Setup

Onyx 2.0 shipped with the default configuration: Ethernet 2x50Gbps, PCIe 2x8.
While customers can change the settings as required, we changed the settings to be Ethernet 1x100Gbps,
and set the IP address to be 3.3.3.1/24.
set-autoneg 1 1 1 2 8; set-autoneg 2 1 1 2 0
Configure the Ethernet to be 100G RS FEC, here is a high-level description of these parameters:
set-autoneg <Port> <TX> <RX> <FEC> <TECH>
<Port> Set to 1 for Ethernet Port #1 and 2 for Ethernet Port #2
<TX> Set to 1 (enables TX Pause Flow Control)
<RX> Set to 1 (enables RX Pause Flow Control)
<FEC> Set to 1 for FC FEC and 2 for RS FEC (100G speed requires RS FRC to be enabled)
<TECH> Selects Ethernet speed (set to 4 for 50G, 8 for 100G. When configured for 100G, TECH
parameter for Ethernet Port #2 must be set to 0 to disable the Port since Fuji supports a single 100G port)
set-ip 1 0 3.3.3.1 255.255.255.0 3.3.3.4 Port1
Configure the IP address of the first Ethernet port.
Note: Refer to Appendix Fuji Profile Configuration for selecting different profile, Onyx boards are shipped with
default profile 0, which supports up to 8 drives. To test 12 drives, please select profile 1. It needs reboot after
profile changed.