Power Interposer Board; Removing The Power Interposer Board - Dell EMC PowerEdge C6400 Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge C6400:
Table of Contents

Advertisement

Figure 40. Installing the cooling fan cage
Next steps
1.
Install the cooling
fans.
2. Follow the procedure listed in
3. Check the management software to see if all the fans are rotating at the optimal speed.

Power interposer board

Removing the power interposer board

Prerequisites
WARNING:
Allow the power interposer board (PIB) to discharge after you power off the system. Handle the PIB by the
edges and avoid touching the contact surfaces of the connectors.
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3.
Remove the power supply
4. Disconnect all the cables from the PIB except for the mid-plane power cables.
Steps
1. To release the PIB from the lock on the chassis, pull the blue release latch.
2. Holding the release latch, lift the PIB up and away from the guide hooks on the chassis.
3. Using the Phillips #2 screwdriver, remove the screws that secure the mid-plane power cables to the PIB.
54
Installing and removing enclosure components
After working inside your
Safety
instructions.
Before working inside your
units.
enclosure.
enclosure.

Advertisement

Table of Contents
loading