Chassis Management Board Specifications; Drives And Storage Specifications - Dell EMC PowerEdge C6400 Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge C6400:
Table of Contents

Advertisement

NOTE:
If system with 1600 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to
800 W.

Chassis management board specifications

Figure 18. Chassis management board specifications
1. Fan cage 1 connector for fans 1 and 2
3. Chassis management board signal cable to backplane
5. Chassis management board signal cable to PIB
7. MCU connector
9. Firmware jumpers
11. Fan cage 2 connector for fans 3 and 4

Drives and storage specifications

The Dell EMC PowerEdge C6400 enclosure supports SAS and SATA hard drives and Solid State Drives (SSDs).
Table 8. Supported drive options for the Dell EMC PowerEdge C6400 enclosure
Maximum number of drives in the enclosure
12 x 3.5-inch drive systems
24 x 2.5-inch drive systems
24 x 2.5-inch drive systems with NVMe
M.2 SATA drive (optional)
Micro-SD card (optional) for boot (up to 64 GB)
22
Technical specifications
2. Left midplane signal cable
4. Chassis management board power connector from PIB
6. FPGA connector
8. COM connector
10. Right midplane signal cable
Maximum number of drives assigned per sled
Three SAS or SATA hard drives and SSDs per sled
Six SAS or SATA hard drives and SSDs per sled
The NVMe backplane supports either of these configurations:
Two NVMe drives and four SAS or SATA hard drives and SSDs
per sled
Six SAS or SATA hard drives and SSDs per sled
The supported capacity of the M.2 SATA card is up to 240 GB
NOTE:
The M.2 SATA card can be installed on the x16
riser slot (slot 5).
One on each PCIe riser of each sled

Advertisement

Table of Contents
loading

Table of Contents