SPECIFICATION OF PV CHARGE CONTROLLER
6. Troubleshooting & Maintenance

6.1 Troubleshooting

The trouble phenomenon and solutions please refer to the
table-1 and table-2 in the last.

6.2 Maintenance

The following inspections and maintenance tasks are
recommended at least two times per year for best performance.
Check the air flow and ventilation around the controller is
not blocked. Clear all dirt or fragments around the exit fan.
Check all the naked wires to make sure insulation is not
damaged for serious sunshine, frictional wear, dryness,
insects or rats etc. Maintain or replace the wires if
necessary.
Check if LCD display. Pay attention to any troubleshooting
or error indication. Take corrective action if necessary.
Tighten all the terminals. Inspect for loose, broken, or
burnt wire connections. Confirm that all the terminals have
no corrosion, insulation damaged, high temperature or
burnt/discolored sign.
Check and confirm that lightning arrester is in good
condition. Replace a new one in time if necessary.
WARNING: Risk of electric shock! Please turn off all the
power when you do these.