Contents General safety instructions Types of notices Basic safety instructions Introduction General description Main features General equipment use Equipment installation and configuration Installation Power connection Quick menu guide Language selection Manual setting Advanced settings Self-installation Maintenance Equipment care Troubleshooting Technical specifications ONE 118 Model (AFP-201) ONE SAT Model (AFP-292) ONE Home Model (AFP-HOME) Technical annex Warranty Equipment recycling CE Certificate...
General safety instructions ReadJallJofJthisJuserJmanualJcarefullyJbeforeJpluggingJinJtheJequipment. AlwaysJhaveJtheseJinstructionsJtoJhandJduringJinstallation. FollowJallJofJtheJinstructionsJandJsafetyJnoticesJregardingJequipmentJhandling. Types of notices TheJmeaningJofJtheJsafetyJnoticesJusedJinJthisJmanualJareJdescribedJbelow. DANGER of DEATH oR INJURY ThisJsafetyJnoticeJindicatesJaJpossibleJdangerJforJtheJlifeJandJhealthJofJpeople.J NotJfollowingJtheseJinstructionsJmayJleadJtoJseriousJconsequencesJtoJhealthJandJ DANGER mayJevenJcauseJfatalJinjuries. RISK of EqUIpmENT DAmAGE ThisJsafetyJnoticeJindicatesJaJpossibleJdangerousJsituation.JNotJfollowingJtheseJ instructionsJmayJleadJtoJtheJequipmentJbeingJdamaged. ATTENTION NoTE ThisJtypeJofJnoticeJisJaJnoteJcontainingJapplicableJadviceJandJusefulJinformationJ forJoptimumJuseJofJtheJequipment. HANDLING THE INSIDE of THE EqUIpmENT IS foRBIDDEN ThisJnoticeJforbidsJanyJworkJthatJmayJaffectJtheJworkingJorderJofJtheJequipmentJ orJitsJwarranty. Do NoT DISpoSE of AS URBAN WASTE ThisJtypeJofJnoticeJindicatesJthatJtheJequipmentJmustJnotJbeJdisposedJofJasJ unselectedJurbanJwaste.
Equipment installation and configuration / Installation Equipment installation and configuration OnlyJtheJLCDJscreenJandJtheJbuttonJareJrequiredJtoJconfigureJtheJequipment.JFollowJtheJ stepsJbelowJtoJinstallJtheJequipmentJandJconfigureJtheJdifferentJparameters. Installation RISK of EqUIpmENT DAmAGE BI-FM BIII-DAB UHF3 UHF2 UHF1 SAT1 MechanicalJhandlingJofJtheJequipmentJ OUTPUT TEST QPSK IN QPSK IN QPSK IN QPSK IN OUTPUT HPA-120 Ref. 4426 BROADBAND AMPLIFIER 47-862 MHz GAIN SYNC...
Page 9
Equipment installation and configuration / Installation Language selection Manual setting Advanced settings Self-installation Filter allocation to aerials (7-0-3) (9-0-1) (10-0-0) (2-7-1) (2-5-3) Filter Adjustment General gain BI - BII input BIII-DAB input UHF output VHF-UHF/EXT input SAT-IF adjustment cloning Lock Input preamps OUTPUT CONF Equipment...
Equipment installation and configuration / Advanced settings SAT-IF output adjustment LNB power configuration NoTE ThereJareJ5JdifferentJconfigurationsJtoJ selectJpolarisation.J LocateJandJselectJpolarisation: NoJpolarisation:JLNB, OFF. b)J 18JVJwithJtones:JLNB, 18 V. c)J 18JVJwithoutJtones:JLNB, 18 V. d)J 13JVJwithJtones:JLNB, 13 V. e)J 13JVJwithoutJtones:JLNB, 13 V. output gain configuration: LocateJ GA JandJselectJlevelJ0 - 20. Emphasis among high frequencies NoTE IfJTILTJisJselected,JtheJequipmentJappliesJ...
Page 14
Equipment installation and configuration / Advanced settings b)J UHF2Jinput:JΨ2, HI / LO. UHF1Jinput:JΨ1, HI / LO. Equipment configuration cloning NoTE CloningJbeginsJautomaticallyJafterJtheJ followingJsteps. ConnectJtwoJequipmentsJusingJaJcoaxialJcableJ inJtheJTestJ1JoutputJofJeachJequipmentJ(seeJ positionJ(15)JinJtheJillustrationJinJtheJGeneral DescriptionJsectionJonJpageJ32). OnJtheJequipmentJreceivingJtheJinformation:J locateJandJselectJMASTER OFF, SLAVE ON. OnJtheJequipmentJsendingJtheJinformation:J locateJandJselectJMASTER ON, SLAVE OFF. NoTE TheJtimeJwaitedJforJcloningJtoJbeJrunJisJ11J seconds.JWhereJcloningJcannotJbeJstarted,J theJequipmentJreturnsJtoJtheJhigherJmenu. Equipment locking NoTE TheJlockJisJenabledJwhenJtheJequipmentJisJ...
Page 15
Equipment installation and configuration / Advanced settings Specific equipment information NoTE InformationJonJtheJequipment,JtheJpro- grammeJversion,JtheJmanufacturingJdate,J theJnumberJofJhoursJoperating,JtheJtem- peratureJandJtheJequipmentJserialJnumberJ areJdisplayedJonJtheJscreen. Restore factory values CAUTIoN ThisJfunctionJwillJmeanJthatJallJpreviousJ configurationsJwillJbeJlostJandJtheJfactoryJ valuesJwillJbeJrestored. SelectJOKJtoJrestoreJfactoryJvalues.J Frequency plan NoTE YouJcanJchooseJbetweenJtwoJdifferentJ channelJallocationsJforJtheJUHFJband.J TheseJallocationsJdependJonJtheJgeo- graphicJterritory.JBy default the equip- ment is configured for the European allocation.
Maintenance Equipment care HANDLING THE INSIDE of THE EqUIpmENT IS foRBIDDEN DoJnotJdismantleJorJtryJtoJrepairJtheJequipment,JitsJaccessoriesJorJitsJcompo- nents.JThisJwillJrenderJtheJwarrantyJnullJandJvoid. DoJnotJuseJtheJpowerJcableJifJitJisJdamaged. ToJdisconnectJtheJpowerJcable,JpullJcarefullyJonJtheJplugJandJnotJtheJcable. ToJcleanJtheJpanelJandJequipmentJconnections: UnplugJtheJequipment. CleanJwithJaJslightlyJdamp,JsoftJcloth.J AllowJtoJdryJcompletelyJbeforeJuse. DoJnotJspillJliquidJontoJtheJequipment.J KeepJventilationJslotsJfreeJofJdustJandJanyJforeignJbodies. Troubleshooting TheJmostJfrequentJproblemsJarisingJduringJequipmentJinstallationJareJindicatedJbelow.JIfJ youJencounterJanyJotherJtypeJofJproblem,JpleaseJcontactJtheJequipmentJsalesJteam. possible cause What to do problem ForgottenJunlockJcode. ContactJyourJpointJofJsale. NothingJdisplayedJonJ TheJpowerJcableJisJnotJcon- CheckJtheJpowerJcable. LCDJscreen. nectedJproperly.J TheJchannelsJdoJnotJ LackJofJsignalJorJunsuitableJ CheckJthatJtheJchannelJ adjustJtoJtheJprogrammedJ channelJlevel.
Equipment recycling RECYCLING of ELECTRICAL AND ELECTRoNIC EqUIpmENT (Applicable in the European Union and in European countries with selective waste collection systems.)J ThisJsymbolJonJyourJequipmentJorJitsJpackagingJindicatesJthatJthisJproductJ cannotJbeJtreatedJasJgeneralJdomesticJwasteJandJmustJbeJhandedJinJatJtheJcor- respondingJpointJofJcollectionJforJelectricJandJelectronicJequipment.JByJensuringJ thisJproductJisJdisposedJofJcorrectlyJyouJwillJhelpJpreventJnegativeJconsequencesJ forJtheJenvironmentJandJhumanJhealth,JwhichJcouldJotherwiseJbeJcausedJbyJinap- propriateJwasteJhandlingJofJthisJproduct.JRecyclingJofJmaterialsJhelpsJpreserveJ naturalJresources.JForJmoreJdetailedJinformationJonJtheJrecyclingJofJthisJproduct,J pleaseJcontactJyourJlocalJcouncil,JyourJnearestJcollectionJpointJorJtheJdistributorJ fromJwhomJyouJpurchasedJtheJproduct.
CE Certificate ByJreproducingJtheJCEJmarking,JIKUSIJguaranteesJequipmentJcomplianceJwithJtheJcor- respondingJharmonisedJstandards. EC-Declaration of Conformity marking We, Manufacturer IKUSI, Angel Iglesias, S.A. Paseo Miramón, 170 E-20009 San Sebastián, Spain declare that the product Programmable Terrestrial&Satellite Multiband Amplifiers is in conformity with E M C L V D Council Directive 2004/108/CE...