B-6
CONTROL LIGHT: ALARM
When the control light (See Figure B.2 item D) blinks
("ALARM"), proceed as follows.
• Stop welding.
• Press filter cleaning ON/OFF - RESET button (See
Figure B.2 item E) to stop the control light from blink-
ing.
• Make sure the FAN ON/OFF switch (See Figure B.2
item C) is off.
• Close throttle valve in extraction hood.
• Press filter cleaning ON/OFF - RESET button again
(See Figure B.2 item E) to start off-line cleaning.
During the off-line cleaning cycle the entire filter car-
tridge is cleaned systematically by compressed airjets.
This cycle takes approximately one hour.
ATTENTION
Do not use the machine during the
off-line cleaning cycle.
------------------------------------------------------------------------
ATTENTION
If desired, the off-line cleaning cycle
can be interrupted by pressing the
filter cleaning ON/OFF - RESET but-
ton (See Figure B.2 item E) .
------------------------------------------------------------------------
After the cleaning cycle is finished, system operation
can be continued.
When you continue welding and the control light starts
blinking again immediately or shortly after the cleaning
cycle is finished, the LongLife filter cartridge is saturat-
ed and should be replaced.
• See Filter Replacement.
WARNING
Saturation or clogging of the filter
cartridge results in a decrease of
the extraction capacity which could
result in a reduced extraction of
welding fumes.
Therefore, stop welding immediately when the
machine enters the ALARM phase.
------------------------------------------------------------------------
MOBIFLEX 400-MS(/HE) BASE UNIT & LFA 3.1/4.1 MOBILE MANUAL/AUTOMATIC
OPERATION

OFF-LINE CLEANING

It is recommended to perform a manual off-line clean-
ing routine a minimum of twice a week.
------------------------------------------------------------------------
------------------------------------------------------------------------
------------------------------------------------------------------------
To perform an off-line cleaning cycle, proceed as fol-
lows.
• Make sure the FAN ON/OFF switch (See Figure B.2
item C) is off.
• Close throttle valve in extraction hood.
• Press filter cleaning ON/OFF - RESET button (See
Figure B.2 item E) to start off-line cleaning.
------------------------------------------------------------------------
ATTENTION
For more efficient filter cleaning, it
is recommended to carry out an off-
line cleaning cycle on a regular
basis.
ATTENTION
For off-line cleaning after working
hours, make sure compressed air is
connected and available.
ATTENTION
The off-line cleaning cycle takes
approximately one hour. Do not use
the machine during the off-line
cleaning cycle.
ATTENTION
If desired, the off-line cleaning cycle
can be interrupted by pressing the
filter cleaning ON/OFF - RESET but-
ton (See Figure B.2 item E) .
B-6