Weatherdock EasyTRX 3 User Manual page 60

Ais class b sotdma
Table of Contents

Advertisement

Weatherdock AG
www.easyAIS.com
Transmitter
As soon as the transponder has send out data
for the first time, the value changes from
"standby" to "OK". If there will be a
malfunction within the unit, the status will be
"Error" and the easyTRX3 is no longer working
proper anymore. Please contact your service
partner. By means of the Error messages more
details are given to you.
Receiver
As soon as the first AIS telegram was send out,
the value changes from "standby" to "OK". If
there will be a malfunction within the unit, the
status will be "Error" and the easyTRX3 is no
longer working proper anymore. Please contact
your service partner. By means of the Error
messages more details are given to you.
Supply Voltage (TX) / Supply Voltage (idle):
This is the voltage value during transmission.
For transmitting AIS data, the easyTRX3 takes
approx. 2A power for 0.2 seconds. If the used
cable are too thin or even too long, the voltage
can drop down under the shown "Idle" value
which might cause to limited transmission
power. To solve the problem, please check the
cable connections or use thicker ones.
TX Forward Power / TX Reverse Power:
Both status will be "OK" if a VHF antenna is
connected in the right way. If the antenna has
got a short circuit or the antenna cable is
interrupted, "Error" is shown here. The ration
between "forward" and "reverse" has to be 3:1
at least or more. As higher the "forward"
value, as better it is. This indicates that most of
the power is transmitted.
Error Info
Within the "Error Messages" area there are
hints to the possible malfunction of the
easyTRX3. These short messages will give more
detailed information about the possible
Seite 60