Settings 
5.1 ISOLATE (SERVICING) MODE 
To prevent the Smoke Screen from making smoke whilst work is conducted with power applied it can be 
put into a servicing mode by selecting the "Isolate" function at the start of the Installer Configuration Menu 
to 'on'. 
FAILURE TO DISABLE ISOLATE WHEN NO LONGER REQUIRED WILL PREVENT THE SMOKE SCREEN 
OPERATING. 
5.2 TAMPER 
There are 4 internal tamper circuits on the Smoke Screen, one on each cover (front, battery and fluid) and 
one through the rear of the case for a bracket tamper. There is also an external tamper input on the PCB 
for the monitoring of peripheral devices. On a tamper alarm the Smoke Screen provides an output 
indication of the event and automatically activates if the Zone 1 (Set) is in alarm. If the Smoke Screen is not 
mounted on its bracket the bracket tamper should be by-passed to prevent unwanted tamper warnings. 
The LCD display and control buttons are disabled if the front tamper is closed. 