4) B/T LEVEL ADJ
After changing the MAIN PCB, adjust WARNING LEVEL and LOCK LEVEL.
< How to adjust >
a...Prepare the POWER..SUPPLY.
b...Connect the camera to the POWER..SUPPLY.
c...Set the voltage to 2.71V.
d...Downloading the program file and save it to SD memory card.
e...Insert the SD memory card and turn on the camera.
f...The adjustment will be done automatically. There are no displays on the LCD.
g...After completing the upgrade, the camera is turned off automatically.
< Description of TXT file >
When making or modifying the program, see the following program codes.
When modify the program, use the Memo Pad of Windows and save it as"STS373ADJ.txt"
/ PM Batch Test 8 //
// adj control
adj_control check_process_id 65535
adj_control set_process_id 65534
adj_control save_e2prom 1 // save eeprom
adj_control save_data_file 1 // save csv...
adj_control save_process_pass 1
adj_control batch 1 // enable 8 adj...
adj_control osd_delay 0
adj_control signal 500// start signal
//adj_control signal 300// start signal
//adj_control signal 300// start signal
// OSD Disable