64
Troubleshooting
Code
Message
P410
Battery Under Voltage
Fault
P411
Battery MisWiring
Fault
P460
Grid L1 Under Voltage Voltage level of the grid (L1) is
P461
Grid L2 Under Voltage Voltage level of the grid (L2) is
P462
Grid L3 Under Voltage Voltage level of the grid (L3) is
P463
Grid L1 Over Voltage
4
P464
Grid L2 Over Voltage
Grid L3 Over Voltage
P466
Grid L1 Over Voltage
10min
P467
Grid L2 Over Voltage
10min
P468
Grid L3 Over Voltage
10min
P469
Grid Over Frequency
P470
Grid Under Frequency
P471
Grid Anti Islanding
P472
Grid L1 DC Offset
Current
P473
Grid L2 DC Offset
Current
Description
Voltage level of the battery is
lower than the limitation and the
state is maintained for more than
10 minutes
Battery MisWiring
lower than the limitation
lower than the limitation
lower than the limitation
Voltage level of the grid (L1) is
higher than the limitation
Voltage level of the grid (L2) is
higher than the limitation
Voltage level of the grid (L3) is
higher than the limitation
The 10minutes average voltage
level of the grid (L1) is higher than
the limitation
The 10minutes average voltage
level of the grid (L2) is higher than
the limitation
The 10minutes average voltage
level of the grid (L3) is higher than
the limitation
Frequency level of the grid is
higher than the limitation
Frequency level of the grid is lower
than the limitation
There was a power failure
DC offset current is added on
grid(L1)
DC offset current is added on
grid(L2)
Solution
Contact service center
Contact service center
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault
Automatically restart after
detecting fault