11 function digital automotive analyser

Advertisement

5.15.4.
Start the engine and the dwell angle will be shown on the display.
note: Refer to vehicle manufacturer's manual for detailed procedures for dwell angle settings and adjustments.
5.16.
replacing the Battery
8 8 Warning! to avoid electric shock, disconnect the test leads from any source of voltage and from the analyser before
8
removing the rear cover.
5.16.1.
When the battery drops below the operating voltage, the
5.16.2.
Remove the analyser from its protective case.
5.16.3.
loosen and remove the two screws using a Phillips screwdriver, and remove the rear cover from the analyser.
5.16.4.
Remove the old battery (PP3) and insert a new one, observing the correct polarity.
5.16.5.
Replace the rear cover and secure with the two screws.
88 Warning! to avoid electric shock, do not operate the analyser until it has been fully re-assembled.
8
5.17.
replacing the fuse
88 Warning! to avoid electric shock, disconnect the test leads from any source of voltage and from the analyser before removing
8
the fuses.
5.17.1.
Remove the analyser from its protective case.
5.17.2.
loosen and remove the two screws using a Phillips screwdriver, and remove the rear cover from the analyser.
loosen and remove the six small screws from the upper circuit board and remove the board to gain access to the fuse holder.
5.17.3.
Remove the old fuse from its holder by gently pulling it out.
5.17.4.
Install the new fuse into its holder.
note: Always use a fuse of the correct size and value, 250mA/250V.
5.17.5.
Replace the rear cover and secure with the screws.
8 8 Warning! to avoid electric shock, do not operate the analyser until it has been fully re-assembled.
8
6.
maintenance
p
Warning! do not attempt to repair or service the analyser unless qualified to do so and have the relevant calibration, performance
test, and service information to hand. To avoid electrical shock or damage to the analyser do not get water inside the case.
6.1.
Periodically wipe the case with a damp cloth and mild detergent. do not use solvents.
6.2.
Turn the analyser off when not in use and remove the battery if stored for a long period of time.
do not store the analyser in a place of high humidity or high temperature.
8
.
Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500
Weee regulations
dispose of this product at the end of its working life in compliance with the eU directive on Waste electrical and electronic equipment
(Weee). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
environment Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
sealey group, Kempson Way, suffolk Business Park, Bury st edmunds, suffolk. iP32 7ar
01284 757500
© Jack Sealey limited
symbol will appear in the display. Replace the battery.
01284 703534
sales@sealey.co.uk
Original Language Version
www.sealey.co.uk
TA102 | Issue:5 (H,F) 01/06/18