Shutdown And Care Of The Pump - Graco A Series Instructions - Parts Manual

Dynamite 190 extruders
Hide thumbs Also See for A Series:
Table of Contents

Advertisement

7. Loosen the clamps (24) and remove the empty can.
Set the full can on the ram base and position it
under the wiper plate.
If the can has a welded seam, position it with the seam
facing the rear of the pump to avoid injury due to splat-
tering fluid if the can leaks at the seam.
8. Lower the ram and adjust the position of the can rel-
ative to the wiper plate. See Start and Adjust the
Ram on page 10.
9. Clamp the can in place.

Shutdown and Care of the Pump

Never leave water or water-based fluid in a carbon
steel pump overnight. If you are pumping
water-based fluid, flush with water first, then with a
rust inhibitor, such as mineral spirits. Relieve pres-
sure, but leave rust inhibitor in the pump to protect
parts from corrosion.
1. Stop the pump at the bottom of the stroke to prevent
fluid from drying on the exposed displacement rod
and damaging the throat packings.
308302U
NOTICE
2. Set the ram director valve to the down position.
F
. 7: Ram Director Valve Position for Shutdown.
IG
3. Follow the Pressure Relief Procedure on page 9.
4. Always flush the pump before the fluid dries on the
displacement rod.
Operation
Ram Director Valve
13