The other possibility is by use of the context menu in the variables list which can also be activated
by a right mouse click.
When
Insert Variable
list. In case of a local variable the function name with a preceeding colon (Function Name :
Variable Name) is entered. With
Delete Variable
variable to be deleted must be selected. The command
from the list.
Under certain circumstances an error message is shown instead of a value in the list:
no Debug Code
wrong Syntax
Function unknown
Variable unknown
not in Debug Mode
no Context
not actual
If a high number of variables is entered in the monitor list it may during single step operation take
quite some time until all variable contents from the module have been scanned. For this reason the
Option
Auto Actualize
then only be displayed after the command
can quickly be operated in single steps and the contents are only actualized on demand.
© 2008 Conrad Electronic
is selected then the variable to be monitored can as text be entered into the
Change Variable
the variable can be entirely erased from the list. Prior to this the line holding the
No Debug Code has been generated
During text entry invalid characters have been entered for a
variable
The Function Name is not known
The Variable Name is not known
The Debug Mode has not been activated
Local variables can only be displayed while within this function
The content of the variable has not been updated
can be switched off for individual variables. The contents of these variables will
the text entry in the list can be altered and with
Delete All Variables
Actualize Variable
is executed. This way the Debugger
IDE
70
will delete all entries