Download Print this page

IBM 3745 21A Installation Instructions Manual page 6

Convert an ibm 3745 model 21a to 31a

Advertisement

Installation Instructions
IBML
Installation (steps 9-11)
9.0 Safety
Review the Safety Notices and the Service
Inspection Procedures located at the begin-
ning of the 3745 Maintenance Information
Procedure (MIP) manual, SY33-2054.
* Steps 10.0 to 10.1.4.
10.0 Details of Installation
Before the installation of this MES ask the cus-
tomer:
To set all lines and channel addresses
offline for this controller and associated
machines.
To provide the maintenance password.
To logoff the Service Processor if not already
done.
10.1 Checking, Diagnostics
10.1.1 MOSS IML
From the control panel:
1. Check that the Power Control indicator
displays 3. If it does not, record the
value __. Then, set the Power Control
indicator to 3.
Press the Validate key.
2. Set the Function indicator to 1.
Press the Validate key.
3. Set the Service Mode indicator to 2.
Press the Validate key.
The MOSS IML is completed when F0E is dis-
played on the control panel.
3745
PN 17G5534
EC C38405
FFBM
6 of 22
06APR93
6
10.1.2 Logon
From the Service Processor:
Administrator Maintenance Mode is displayed on
the lower line of the window.
10.1.3 Open MOSS/MOSS-E Session
Wait for Function Selection Rules screen.
10.1.4 Disable Channels Adapters
10.1.5 Verify the CDF
EC C38405A
EC D55799
17JUN93
16SEP94
1. In MOSS-E View window, click on
Program.
2. Click on LOG ON MOSS-E.
3. Enter the maintenance password, press
Enter.
1. On the MOSS-E View window, double
click on the ICON of the identified 3745.
2. On the 3745 Menu window, double click
on MOSS Console.
1. Enter CID, press Enter.
2. On the CA Interface Display screen,
record the Enable Channel Adapters, then
Disable all the Channel Adapters.
Note: If 3746 A11 is installed, press F8 to
display channels 8 through 16.
3. Wait for Interface Status Disabled for all
channels.
4. Press F1.
5. If CCU running, enter RST to reset the
CCU.
MOSS goes in MOSS ALONE state.
1. Enter CDF, press Enter.
2. Enter 4 (VERIFY), press Enter.
The value from the CDF DATA and
MACHINE DATA should be identical.
If there is a discrepancy, verify the fea-
tures. If correct, update the CDF with the
machine values, enter 2, press Enter.
EC D55883
EC E27926
11MAY95
14MAR97