Download Print this page

IBM 3745 21A Installation Instructions Manual page 11

Convert an ibm 3745 model 21a to 31a

Advertisement

Installation Instructions
IBML
10.4 CCU Enclosure Exchange
CAUTION:
The CCU enclosure can weight up to 37 kg (81.5
lb).
An additional person may be needed because of
the weight of the enclosure unit.
The first person is placed on the right side of the
enclosure, the second on the left side, and the
third, if needed, at the front of the enclosure
using the provided handhold.
Note: Ensure that all flat cables are protected
from damage during the CCU enclosure
exchange.
10.4.1 TCM Enclosure Removal
1. Remove the 4 screws
CCU enclosure.
2. Pull the complete enclosure partially out
of the 3745 (approximately 15 cm).
3745
PN 17G5534
EC C38405
FFBM
11 of 22
06APR93
1
securing the
EC C38405A
EC D55799
17JUN93
16SEP94
3. From the rear of the 3745, attach the
handhold (PN 76F9076)
sure as shown on the figure below. This
will allow the third person involvement.
The handhold is clipped to the right and
left sides of the CCU enclosure (see view
B). Secure the handhold with the
attached pins.
4. Two persons grasp the enclosure
assembly by the handhold
SACL board. The third person, if
needed, grasps the front handhold
Slide the assembly out of the 3745.
5. Put the enclosure in a safe place.
6. Install 3 clamps (PN 34F1295) as follows:
Remove the clamp
clamp 9 cm (3.5 in.) to the left.
Remove the clamp
3 cm (1.1 in.) to the right.
Remove the clamp
1 cm (0.4 in.) to the right.
EC D55883
EC E27926
11MAY95
14MAR97
3
to the enclo-
2
and at the
3
.
4
, and stick a
5
and stick a clamp
6
and stick a clamp
11

Advertisement

loading

This manual is also suitable for:

3745 31a