We recommend that installation is carried out by skilled persons with technical qualifications required by the specific legislation in force. 1.2 Hazard statements The symbols and hazard statements below may appear in Grundfos installation and operating instructions, safety instructions and service instructions.
Page 6
Mechanical installation DANGER Electric shock Death or serious personal injury ‐ Switch off the power supply before you start any work on the product. ‐ Make sure that the power supply cannot be switched on accidentally. CAUTION Sharp element Minor or moderate personal injury ‐...
Touch only the buttons on the display. The product may be very hot. WARNING Electric shock Death or serious personal injury ‐ If the operating panel is cracked or perforated, replace it immediately. Contact the nearest Grundfos sales company. Service DANGER Electric shock Death or serious personal injury ‐...
• Provide the product with a suitable cover. The cover must be large enough to ensure that the product is not exposed to direct sunlight, rain or snow. Grundfos does not supply covers. When fitting a cover to the product, observe the instructions for adequate cooling.
Page 9
• Open the drain holes in the product. • Connect the product permanently to the mains supply and activate the built-in standstill heating function. 4.1.5 Installation altitude The installation altitude is the height above sea level of the installation site. Products installed up to 1000 m above sea level can be loaded 100 %.
‐ Use lifting equipment. Do not lift the product by the terminal box. To protect components such as pressure gauge, sensor and tank, Grundfos recommends lifting the product in the same packing it was delivered in. • Always lift the product by means of a forklift if the pump is fixed on a pallet.
Check that the supply voltage and frequency correspond to the values stated on the nameplate. If you want to supply the product through an IT network, make sure that you have a suitable product variant. If you are in doubt, contact Grundfos. Mains connection on a single-phase motor...
Page 12
Pos. Description Protective earth Phase Neutral 4.3.5 Residual-current circuit breakers DANGER Electric shock Death or serious personal injury ‐ If national legislation requires a Residual Current Device (RCD) or equivalent in the electrical installation, this must be type B or better, due to the nature of the constant DC leakage current.
• two analog inputs • two digital inputs or one digital input and one open-collector output • Grundfos Digital Sensor input and output • two signal relay outputs • GENIbus connection. The inputs and outputs are internally separated from the mains-conducting parts by reinforced insulation and galvanically separated from other circuits.
Page 14
+24 V* DI3/OC1 +24 V* +24 V* +24 V*/5 V* +5 V GENIbus A GENIbus Y GENIbus B +24 V +24 V +5 V GDS TX +24 V* +24 V* +24 V*/5 V* GDS RX +5 V* Terminal Type Function Normally closed contact Common Signal relay 1.
Grundfos Eye is off The power is off. Operation Pump running Ready Alarm Warning Operating mode Grundfos Eye is rotating green The pump or motor runs in Normal mode in open or closed loop. Operation Pump running Ready Alarm Warning Operating mode Normal Min.
Page 16
Operation Pump running Ready Alarm Warning Operating mode Normal Min. Max. Grundfos Eye is rotating yellow Warning, but the pump or motor is running. Operation Pump running Ready Alarm Warning Operating mode Manual Grundfos Eye is permanently yellow Warning, but the pump or motor was stopped via a Stop command.
Let the booster system run for 30 seconds to let all remaining air out of the system. The pumps are factory set, so the booster system pressure will stabilise at factory setpoint and Grundfos Eye will show a steady green light.
Grundfos CMBE TWIN booster is suitable for clean water supply and pressure boosting in domestic and commercial applications. The booster system maintains a constant pressure in the pipe system. The CMBE TWIN booster system consists of two CMBE boosters that operate in parallel.
The CMBE TWIN booster system is typically used for pressure boosting in larger applications in blocks of flats, hospitals, hotels, schools, and small industrial plants and businesses, agriculture and irrigation. 6.3 Pumped liquids The product is suitable for pumping clean, thin, non-aggressive, non-toxic and non-explosive liquids without solid particles or fibres.
If you use a bus signal, the local settings made via Grundfos GO Remote or the advanced operating panel will be overruled. In case the bus signal fails, the product will run with the local settings made via Grundfos GO Remote or the advanced operating panel.
Grundfos GO Remote. The green indicator light in the middle is You have selected the motor in Grundfos GO Remote, and the motor flashing continuously. is ready to be connected.
Electric shock Death or serious personal injury ‐ If the operating panel is cracked or perforated, replace it immediately. Contact the nearest Grundfos sales company. You can set the product by means of the following user interfaces: • Operating panel on the product •...
8.2.1 Grundfos GO Remote The product is designed for wireless radio or infrared communication with Grundfos GO Remote. Grundfos GO Remote enables you to set functions and gives you access to status overviews, technical product information and current operating parameters.
If two or more functions are enabled at the same time, the motor operates according to the function with the highest priority. If you have set the motor to maximum speed via the digital input, the motor operating panel or Grundfos GO Remote can only set the motor to Manual or Stop.
Start Stop and Maximum speed settings made with Grundfos GO Remote or on the motor operating panel can be overruled by another operating-mode command sent from a bus, for exampleStart. If the bus communication is interrupted, the motor resumes its previous operating mode, for example Stop, that was selected with Grundfos GO Remote or the motor operating panel.
Check if the external motor protection has tripped. • Check cables and cable connections for defects and loose connections. 11.2 The pump rotates backwards No light indication in Grundfos Eye. Cause Foot valve or non-return valve is clogged or defective. •...
Miscellaneous data Pump: IP55 Enclosure class Sensor: IP44 Insulation class 12.1 Leakage currents for CMBE TWIN Single-phase motors The leakage currents are measured in accordance with EN 61800-5-1:2007. Product Earth leakage current (AC) [mA] CMBE (one pump running) < 3.5 mA CMBE TWIN (two pumps running) ≥...
Conductor types Stranded or solid copper conductors. Conductor temperature ratings Temperature rating for conductor insulation: 60 °C (140 °F). Temperature rating for outer cable sheath: 75 °C (167 °F). 12.4 Inputs and outputs Earth reference All voltages refer to earth. All currents return to earth. Absolute maximum voltage and current limits Exceeding the following electrical limits may result in severely reduced operating reliability and motor life.
Page 30
If this is not possible, contact the nearest Grundfos company or service workshop. Dispose of the waste battery through the national collective schemes. If in doubt, contact your local Grundfos company. The crossed-out wheelie bin symbol on a product means that it must be disposed of separately from household waste. When a product marked with this symbol reaches its end of life, take it to a collection point designated by the local waste disposal authorities.
Page 31
Declaration of conformity GB: EC/EU declaration of conformity DE: EG-/EU-Konformitätserklärung We, Grundfos, declare under our sole responsibility that the Wir, Grundfos, erklären in alleiniger Verantwortung, dass die products CMBE, to which the declaration below relates, are in Produkte CMBE, auf die sich diese Erklärung bezieht, mit den...
Page 32
Applies from 22.07.2019: RoHS Directives (2011/65/EU and 2015/863/EU) Standards used: EN 50581:2012. This EC/EU declaration of conformity is only valid when published as part of the Grundfos installation and operating instructions (publication number 99352825). Bjerringbro, 30/11/2018 Florian Joseph Program Engineering Manager...
Page 33
Часть 3: информация о сроке изготовления, размещенная на фирменной табличке изделия. Сведения о сертификации: Насосные установки типа CMBE TWIN сертифицированы на соответствие требованиям Технических регламентов Таможенного союза: ТР ТС 004/2011 «О безопасности низковольтного оборудования»; ТР ТС 010/2011 «О безопасности машин и оборудования»; ТР ТС...
Page 34
3 бөлім: өнімнің фирмалық тақташасында орналасқан шығарылған уақыты жөніндегі мәлімет Сертификаттау туралы ақпарат: CMBE TWIN типті сорғы қондырғылары «Төмен вольтты жабдықтардың қауіпсіздігі туралы» (ТР ТС 004/2011), «Машиналар және жабдықтар қауіпсіздігі туралы» (ТР ТС 010/2011) «Техникалық заттардың электрлі магниттік сәйкестілігі» (ТР ТС 020/2011) Кеден Одағының...
Page 35
3-Бөлүк: жабдуунун фирмалык тактасында жайгашкан даярдоо мөөнөтү тууралуу маалымат. Шайкештик жөнүндө декларация CMBE TWIN түрүндөгү соргучтар орнотуу Бажы Биримдиктин Техникалык регламенттин талаптарына ылайыктуу тастыкталган: ТР ТБ 004/2011 «Төмөн вольттук жабдуунун коопсуздугу жөнүндө»; ТР ТБ 010/2011 «Жабдуу жана машиналардын коопсуздугу жөнүндө»; ТР ТБ...
Page 36
փաստաթղթի վերջում նշված հղումով. Մաս 3. տեղեկություն արտադրման ամսաթվի վերաբերյալ՝ նշված սարքավորման պիտակի վրա: Տեղեկություններ հավաստագրման մասին՝ CMBE TWIN տիպի պոմպերը Տեղադրեք սերտիֆիկացված են համաձայն Մաքսային Միության տեխնիկական կանոնակարգի պահանջների՝ ТР ТС 004/2011 «Ցածրավոլտ սարքավորումների վերաբերյալ», ТР ТС 010/2011«Մեքենաների և սարքավորումների...
Page 37
Tel.: +387 33 592 480 Centre Turkey Fax: +387 33 590 465 29-33 Wing Hong Street & 68 King Lam GRUNDFOS Pumper A/S GRUNDFOS POMPA San. ve Tic. Ltd. Sti. www.ba.grundfos.com Street, Cheung Sha Wan Strømsveien 344 Gebze Organize Sanayi Bölgesi E-mail: grundfos@bih.net.ba...
Need help?
Do you have a question about the CMBE TWIN and is the answer not in the manual?
Questions and answers