CLGCH60-CR1 / CLGCH70R1 / CLGCH90-CR1 Cooker Hood
Technical and legal information
The Manufacturer declines all liability for damage caused to persons and objects
due to incorrect or improper installation of the appliance.
Electrical Requirements
Any permanent electrical installation must comply with the latest I.E.E. regulations
electrician or contractor who is on the roll of the National Inspection Council
for Electrical Installation Contracting (NICEIC) should undertake the electrical
installation.
Electrical Connection
Before connecting the mains supply ensure that the mains voltage corresponds to
the voltage on the rating plate inside the appliance.
WARNING: THIS APPLIANCE MUST NOT BE EARTHED
The appliance is supplied with a 2-core mains cable and must be connected to
the electricity supply via a double pole switch having a 3mm minimum contact gap
on each connector.
For UK only
A Switched Fused Connection Unit to BS 1363 Part 4 is recommended.
The fuse must be rated at 3 Amps.
The wires in the mains lead are coloured in accordance with the following code:
Brown = L - Live
Blue = N - Neutral
The connection point must be placed in a position adjacent to the appliance so as
to be readily accessible for an engineer in the event of a breakdown.