Minolta EP5000 Disassembly And Reassembly page 45

Hide thumbs Also See for EP5000:
Table of Contents

Advertisement

1156SBD0205A
2-5. Imaging Unit
(1) Removal of the Imaging Unit
1136D150AA
1156D055AA
(2) Disassembly of the Imaging Unit
1136D152AA
1156D056AA
1156D057AA
1.
Swing down the Front Door.
2.
Swing the Transport Section Release Lever down.
3.
Loosen two screws that secure the IU.
4.
Slide out the IU.
1.
Remove the PC Drum Charge Corona by moving it to the
rear.
2.
Loosen one screw and remove the stopper.
3.
Remove the PC Drum.
4.
Pull the Main Hopper to the front and unplug two Hopper
Unit connectors.