  • Page 1 Installation & Configuration manual InduBox GSM M4 V1.1...
  • Page 2 ! CAUTION ! ELECTRIC SHOCK HAZARD IF COVER REMOVED SERVICE BY QUALIFIED PERSONEL ONLY Document History Date Version Auteur 29/01/18 V1.0 Preliminary Filip Lavaerts Creation / V1.0 InduBox GSM M4 hardware manual 28/05/18 V1.1 Preliminary Filip Lavaerts Adding/edit Wouter’s info about configuration...
  • Page 3: Table Of Contents

    SIM Card Ports and Connectors Mains Power Connection Isolated DTE Interfaces Isolated RS-232 connection Isolated RS-485 connection Pin 1 Ethernet interface Antenna interface Non isolated DTE interface LED Indicators InduBox GSM M4 HTML GUI Configuration EC-declaration of conformity Basic Dimensions...
  • Page 4 Serial flow as used in this manual : Data Data Communication Terminal Equipment Equipment Modem InduBox GSM M4 Communication Application device...
  • Page 5: Introduction

    Introduction This manual is the reference when setting up the InduBox GSM M4 modem for your application. Because of the nature of this product and its field of application, some degree of technical background knowledge regarding the application and data- communication is assumed.
  • Page 6: Block Diagram

    STM32 F4 – CORTEX M4 AC/DC power supply The mains supply (ac) must be connected to the InduBox GSM M4 modem via a 2 pin terminal block with screw contacts. Make sure the voltage supplied to the modem is in the range of the InduBox GSM M4 input voltage (see specifications for details on voltage range).
  • Page 7 Isolated DTE interfaces The InduBox GSM M4 has 2 galvanically isolated serial interfaces : 3- wire RS-232 (RxD, TxD, GND’) 3- wire RS-485 (A, B, GND’) Those interfaces are galvanically separated and can be used to connect a serial device.
  • Page 8: Specifications

    -25°C / + 55°C Humidity in use 10% - 75% (non condensing) Power Supply Specifications Input voltage range: 90 – 253 Vac Input frequency: 47 – 63 Hz Power: 1,8 W idle Disconnect the mains power before opening the InduBox GSM M4 modem!
  • Page 9: Sim Card

    How to install the SIM card: 1. Disconnect the mains power and DTE interface. 2. Open the InduBox GSM M4 enclosure. 3. The SIM cardholder is placed in the upper right corner onto the PCB. 4. Slide the upper part to the LEFT position.
  • Page 10: Ports And Connectors

    Make sure the voltage supplied to the modem is within range of the InduBox GSM M4 input voltage (see specifications for details on voltage range). There is no fuse or circuit breaker built-in to the InduBox GSM M4, this must be added externally.
  • Page 11: Isolated Dte Interfaces

    The isolated serial interfaces are galvanically separated from the main circuits of the InduBox GSM M4 ; the RxD and TxD lines are separated via an OptoCoupler, a second 5 Vdc power supply is created via an additional DC/DC convertor.
  • Page 12 UART 5V’ 5V’ TTL/V.10 Level Shift GND’ 5.2.2 Isolated RS-485 interface To be used when a RS-232 device must be connected to the InduBox GSM M4. • Jumper settings JP7 JP8 JP7 & JP8 on position ‘4’ Meter • Connection...
  • Page 13 JP7 JP8 Pin 1 is connected to a DI (digital input via an optocoupler). An input voltage of 5 to 25Vdc is needed to activate the DI. Meter Depending on the firmware this can for example reset the InduBox GSM M4.
  • Page 14 Ethernet interface This 10/100 Mbit/s LAN interface is primarily used to configure the InduBox GSM M4. Default IP address is 192.168.1.44 / 255.255.255.0. HTML is available on standard port 80. Antenna interface The GSM antenna must be connected on the GSM modem via a cable, depending on the application and the GSM RF field strength at the site.
  • Page 15: Pin V.24

    This interface can be used to connect a standard serial device or to configure or debug the InduBox GSM M4. This interface is accessible via a RJ-45 8-pin connector, is not galvanically isolated and has all standard V.24 interface lines. A RJ-45 to a standard female DB-9 connector cable is available.
  • Page 16: Led Indicators

    LED Indicators There are 8 LED’s located onto the InduBox GSM M4 modem printed circuit. green RSSI: Received Always ON : +CSQ==99 Signal Strength, 1 periodical flash: +CSQ >10 indicating the 2 periodical flash: +CSQ 10-14 received power level. 3 periodical flash: +CSQ 15-19...
  • Page 17: Indubox Gsm M4 Html Gui Configuration

    InduBox GSM M4 HTML GUI Configuration Configuration of the InduBox GSM M4 can be done through a GUI via HTML. The default ip address of the modem is 192.168.1.44. Username : admin Password : password Click on “login” to enter the configuration pages of the modem.
  • Page 18 Status Displays the most important configuration. General System info • Software Version • Uptime: time passed after power-on or reset of the modem LAN - Info about the local Ethernet interface: • IP Address • Netmask • MAC Address WAN - Info about the WAN interface, which is the connection over the mobile network: •...
  • Page 19 Configuration To change the configuration: change the parameter, press Save Changes on the same page and Reboot the module. Configuration of the local Ethernet interface. • IP Address: Set the IP address of the local Ethernet interface • Subnet Mask •...
  • Page 20 Serial configuration of the serial port. Configuration Interface RS-232 - Set the serial parameters of the RS-232 configuration interface. These parameters should match the parameters of the connected device. • Baud rate • Data Bits • Parity • Stop Bits •...
  • Page 21 Configuration of the WAN connection over the mobile interface. General • SIM PIN: pin code for the installed SIM card. If the SIM pin is disabled, the entered SIM pin will not be sent. • Additional init string after startup: at commands that will be executed at startup. Only certain AT-commands are allowed, others are discarded.
  • Page 22 Watchdog functions • Connection Teardown Timeout: Only applicable in CSD or TCP server or client mode. The connection will be disconnected if this timeout expires when there is no data received/sent on the connection. ◦ CSD: Connection is closed after this timeout with no data sent/received. ◦...
  • Page 23 CSD - Transparent serial communication Creates a transparent serial connection, RS-232 or RS-485, over a 2G CSD data call. Serial connection at the InduBox side can be made from the configuration interface (full RS-232) or the isolated interface (3-wire RS-232 or 2-wire RS-485). Incoming connections will be forwarded to the selected interface.
  • Page 24 Working mode: basic router Configuration of the basic router working mode. This mode will make a transparent IP connection from the Ethernet port to the connected mobile network. Incoming traffic for LAN • Filter: only allow connections from the given subnet (ip address and netmask, use netmask 255.255.255.255 to only allow one specific IP address) •...
  • Page 25 Administration Traces Configuration of the debug traces that are printed to the configuration interface (if this interface is not used, see configuration → serial page). For each topic there are 3 levels of prints, with different amounts of prints (info>warning>error). Change Admin Password Change the password used to access the configuration web page.
  • Page 26: Ec-Declaration Of Conformity

    EC-Declaration of conformity standard CE + TST25-3 (additional extended immunity tests) EN61000-3-2 Electromagnetic compatibility, part 3, section 2 Limits for harmonic current emissions. EN61000-3-3 Electromagnetic compatibility, part 3, section 3 Limitations of voltage fluctuation and flicker. EN61000-4-2 Electromagnetic compatibility, part 4, section 2 Electrostatic discharge immunity test.
  • Page 27 CISPR24 levels EN61000-4-11 Electromagnetic compatibility, part 4, section 11 Voltage dips, short interruptions and voltage variations immunity test. CISPR24 levels EN61000-4-18 Oscillatory waves 1 MHz 2,5 KV, rep rate 400 Hz applied on mains in common mode 100 Khz 2,5 KV, rep rate 40Hz applied on mains in common mode 1 MHz 1KV, rep.