Figure 1-2, Electrical Connection Points - Magnum Energy MagnaSine MS-PE Series Owner's Manual

Pure sine wave inverter
Table of Contents

Advertisement

DC Equipment Ground Terminal – this connection is used to tie the exposed chassis
7
of the inverter to the DC grounding system. This terminal accepts CU/AL conductors from
2.1 to 33.6 mm
AC Entry/Exit Connections – two 3/4" knockouts provided with cable-clamp
8
reliefs to accommodate and secure the AC input and output
Intake Air Vents – ventilation openings to pull in air to help keep the inverter cool for
9
peak performance. The intake air vents are located on the front side and at the front on
the right side; see Figure 2-3 for the locations of the air vents.
Positive DC Terminal (red) – provides a 360 degree connection point for the positive
10
(+) cable from the battery bank; consists of a 5/16-18 x 5/8" bolt with a Kep or Flange
nut that holds the battery cable to the DC terminal.
Negative DC Terminal (black) – provides a 360 degree connection point for the negative
11
(-) cable from the battery bank; consists of a 5/16-18 x 5/8" bolt with a Kep or Flange
nut that holds the battery cable to the DC terminal.
12
Mounting Flange – used to secure the inverter to a shelf or to a wall.
8
AC Entry/Exit
Connections
7
DC Equipment
Ground Terminal
© 2013 Magnum Energy, Inc.
(#14 to #2 AWG).
2
Intake Air Vents
(and on right side)

Figure 1-2, Electrical Connection Points

Introduction
fi eld
wiring.
9
strain
10
Positive (+)
DC Terminal
11
Negative (-)
DC Terminal
12
Mounting
Flange
Page 4

Hide quick links: