9

TECHNICAL DATA

Converter Series CG ®
Part-No. Converter
Part-No.Converter cartridge Type
C Carbon-Molybdenum
Part-No.Converter cartridge Type
SS metallic Filling
Gas inlet and –outlet non-heated
(cold) or heated (hot)
Bypass solenoid valves
Gas inlet temperature
Temperature range, adjustable
Gas flow rate
Operating pressure
Warm-up time
Volume of the converter cartridge
Operating temp. converter car-
tridge type C
Operating temp. converter car-
tridge type SS
Max. NO
concentration
2
Conversion rate NO
in NO
2
Service life of the NO
/NO catalyst
2
Differential pressure
Ambient temperature
Storage temperature
Relative air humidity
Connection sample gas inlet and
outlet
Power
Power consumption
Electrical connections
Status signals for temperature
Material of sample contacting parts
Degree of protection
Housing
Weight
Electrical equipment standard
Option for CG-2 and CG-2M
* Standard ø 6 mm connection, optional ø ¼" – please indicate with order.
** The indicated service life of 6 respectively 12 months is the minimum service live of the catalyst material under
normal conditions and in not highly corrosive, reducing or oxidizing atmospheres. The operator is responsible for
checking and, if necessary, adjusting the life cycles.
www.mc-techgroup.com
CG-2
CG-2M
50A1600(a)
50A1500(a)
Non-heated
Non-heated
--------
2 x
Max. +80 °C [176 °F],
dew point "dry"
Max. 680 °C [1256 °F]
30 to 60 Nl/h, max. 90 Nl/h
Max. 2 bar abs. (pressure deviations only with max. 0.1 bar/min)
Min. 320 °C [608 °F] typ. 350 °C [662 °F] max. 380 °C [716 °F]
Min. 620 °C [1148 °F] typ. 660 °C [1220 °F] max. 680 °C [1256 °F]
200 ppm (type C), 2000 ppm (type SS) at new catalyst
Effectiveness > 95 % for a new catalyst
Change as a preventive measure every 6 months for type C**
Change as a preventive measure every 12 months for type SS**
< 20-60 mbar depending on type
+10 to +50 °C [50 to 122 °F]
-25 to +65 °C [-13 to 149 °F]
PVDF-fitting G1/4 i DIN 228/1
230 V 48-62 Hz
or 115 V 48-62 Hz (a)
520 W
Mains power plug connector incl. 2 fine fuses 5 x 20 mm,
230 V / 3.15 A
2 m [approx. 6.56 ft] cable with shockproof plug.
Alarm- and control signals 9 pin Sub-D-connector
1 Contact potential free, max. contact rating 24 V, 1 A
Stainl. Steel SS316Ti, PTFE, FPM, PVDF
19" rack mounting,
3U, depth 350 mm [13.78"]
Approx. 6 kg [13.23 lb]
EN 61010, EN 60519-1
Mounting bracket, 3U – 84HP, Part No.: 50A3000
CG-2 | 1.04.00
CG-2H-W
50A1900(a)
95A9003
95A9004
Heated
--------
Max. +250 °C [482 °F],
dew point <160 °C [320 °F]
Approx. 30 min.
Approx. 35 cm
3
< 80 %
ø6 mm tube fitting, 1.4571*(316Ti*)
230 V 48-62 Hz
or 115 V 48-62 Hz (a)
620 W
or 115 V / 6.3 A
TT
T
IP20, EN 60529
Wall mounting,
height 350 mm [13.78"], depth 3U
CG-2MH-W
50A1920(a)
Heated
1 x
940 W
,
Stainl. Steel
SS316Ti, PTFE,
FPM, PVDF, alu-
minium hard-
coated
15