Mitsubishi Electric PAC-IF021B-E Manual page 33

Table of Contents

Advertisement

6
Controller operation (FTC)
Function Selection of remote
controller
Standard Control Screens
OFF
TIME SUN
˚C
˚C
TEMP.
2
1
3
2
TIME SUN
˚C
TEMP.
Set Day/Time
TIME SUN
˚F˚C
˚C
ON
1
Day of the Week
& Time display
9
ON/OFF
4
Day of the Week Setting
Time Setting
4
˚C
ON/OFF
1
1
<Screen confi guration>
For details on setting the language for the remote controller dis-
play, refer to 6.5. Function Selection.
The initial language setting is English.
● Function Selection of remote controller:
Set the functions and ranges available to the remote
controller (timer functions, operating restrictions, etc.)
● Set Day/Time:
Set the current day of the week or time.
● Standard Control Screens:
View and set the air conditioning system's operating
status
<How to change the screen>
A : Hold down both the Mode button 2 and the Timer On/Off but-
ton 9 for 2 seconds.
B : Press either of the Set Time buttons (
c : Press the Mode button 2.
6.2. Setting the day of the week and time
1. Press the
or
Set Time button 1 to show display 2.
2. Press the Timer On/Off (Set Day) button 9 to set the day.
* Each press advances the day shown at 3 :
Sun → Mon → ... → Fri → Sat.
3. Press the appropriate Set Time button 1 as necessary to set the
time.
* As you hold the button down, the time (at 4) will increment
fi rst in one-minute intervals, then in ten-minute intervals, and
then in 1-hour intervals.
4. After making the appropriate settings at Steps 2 and 3, press the
button 4 to lock in the values.
Note:
The day and time will not appear if clock use has been dis-
abled at Function Selection of remote controller.
6.3. Operation
Available items are different depending on your system.
(Refer to section 2.)
6.3.1 Switching
<To Start Operation>
■ Press the ON/OFF button 1.
• The ON lamp 1 and the display area come on.
Note:
When the unit restarts, the previous settings are recalled as
follows.
Remote controller setting
Mode
Last operation mode
Temperature setting
Last set temperature
<To Stop Operation>
■ Press the ON/OFF button 1 again.
• The ON lamp 1 and the display area goes dark.
Note:
Even if you press the ON/OFF button to restart the system
while turning down the operation, the outdoor unit will not
start for about 3 minutes.
This is to prevent the internal components from being dam-
aged.
Flow temp. controller
or
) 1.
C-33
C-33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pac-if031b-e

Table of Contents