Download Print this page

Configuration; Power-Up; Temperature Setting; Operating Modes - Honeywell 08160 Manual

Advertisement

Configuration

The configuration switches are on the back of
the thermostat. The factory settings are indi-
cated by the gray cells in the following table.
a
SW1 Early Start
b
SW2 Display format
c
SW3 Cycle length
SW4 Not used
a. Early Start can be used in Automatic mode only. When this func-
tion is enabled, the thermostat calculates the optimal time to start
heating in order to obtain the desired temperature by the set time.
The thermostat re-assesses the start time daily based on the pre-
vious day's performance.
b. If you change the temperature display format, the preset
temperatures ( ,
and
c. 15-second cycles should be selected in most cases as it provides
better temperature control. 15-minute cycles must be selected if
you have a fan-equipped heater or if 15-second cycles causes
light flickering (especially in rural regions).

Power-up

Upon power-up, the thermostat is in manual mode ( ) and displays
the actual (ambient) temperature.
Press the Hour and Min buttons to set the thermostat's clock.
Press the Day button to set the day.

Temperature Setting

Setpoint
The thermostat normally displays the actual temperature. To view the
setpoint, press the
or
button briefly. The setpoint will appear for
the next 5 seconds.
To change the setpoint, press the
temperature is displayed. To scroll faster, hold the button.
Using a preset temperature
The thermostat has 3 preset temperatures:
Comfort temperature
Economy temperature
Vacation temperature
Icon
Intended use
Comfort (when at home)
Economy (when asleep or away from home) 62 °F (16.5 °C)
Vacation (during prolonged absence)
To use the Comfort or Economy temperature, press the
button respectively. The corresponding icon will be displayed.
To use the Vacation temperature, press both
simultaneously. The
icon will be displayed.
Storing a preset temperature
To store the Comfort or Economy temperature:
Set the desired temperature using the
hold the appropriate button (
onds until the corresponding icon is displayed. Press the Mode
button.
08060 / TH106 / TL6061
Programmable Thermostat - Installation and User Guide
Off
°C / 24-hour
°F / 12-hour
15 seconds
15 minutes
-
) will return to their default settings.
or
button until the desired
Factory setting
70 °F (21 °C)
50 °F (10 °C)
and
or
button. Press and
or ) for approximately 3 sec-
To store the Vacation temperature:
3.
Set the desired temperature using the
hold both
seconds until the

Operating Modes

Automatic - The temperature is set according to the programmed
schedule. To place the thermostat in this mode, press Mode until
On
displayed. The icons of the current period and preset temperature
are also displayed.
Temporary Bypass: If you modify the setpoint (by pressing the
-
,
,
the new setpoint will be used until the end of the current period.
When the next period starts, the temperature set for that period
becomes the new setpoint.
Manual - The programmed schedule is not used. The temperature
must be set manually. To place the thermostat in this mode:
Press Mode until
Set the temperature using the
Schedule
The schedule consists of 4 periods per day which represents a typi-
cal weekday. You can program the thermostat to skip the periods that
4.
do not apply to your situation. For example, you can skip periods 2
and 3 for the weekend.
Period
5.
The Comfort ( ) temperature is used in periods 1 and 3 and the
Economy ( ) temperature is used in periods 2 and 4. For example,
when the period changes from 1 to 2, the setpoint automatically
changes from Comfort setting ( ) to Economy setting ( ).
You can have a different program for each day of the week; i.e., each
period can start at different time for each day of the week. The
thermostat has been programmed with the following schedule.
Period
Setting
or
buttons
To modify the schedule:
Press Pgm to access the programming mode. Period 1 is
selected.
Press Day to select the day to program (hold for 3 seconds to
select the entire week).
Press Hour and Min to set the start time of the selected period,
or press Clear if you want to skip the period (--:-- is displayed).
Press Pgm to select another period, or press Day to select
another day. Then repeat step 3.
and
buttons simultaneously for approximately 3
icon is displayed. Press the Mode button.
or
button) when the thermostat is in automatic mode,
is displayed.
,
,
Description
Associated temperature preset
Wake
Leave
Return
Sleep
MO
TU
WE
TH
6:00
6:00
6:00
6:00
AM
AM
AM
AM
8:00
8:00
8:00
8:00
AM
AM
AM
AM
6:00
6:00
6:00
6:00
PM
PM
PM
PM
10:00
10:00
10:00
10:00
PM
PM
PM
PM
69-2024
or
button. Press and
6.
is
or
button.
7.
FR
SA
SU
6:00
6:00
6:00
AM
AM
AM
8:00
--:--
--:--
AM
6:00
--:--
--:--
PM
10:00
10:00
10:00
PM
PM
PM
1/11/06