Changing Parameters - ABB CL Series Applications Manual

Hide thumbs Also See for CL Series:
Table of Contents

Advertisement

1SVC 440 795 M1100

Changing parameters

T 03 Ü
S
CP08
C 17
L:
1
RUN
The display system allows you to change function relay
parameters such as timing relay setpoint values and counter
setpoints without having to call up the circuit diagram. This
is possible regardless of whether the display system is
running a program or is in STOP mode.
Press OK to switch to the main menu.
X
Start the parameter display by selecting PARAMETER.
X
All function blocks are displayed as a list.
+
-
The following preconditions must be fulfilled in order for a
+
parameter set to be displayed:
• A function relay must have been included in the circuit
diagram.
• The PARAMETER menu must be available.
• The parameter set must have been enabled for access,
indicated by the + character at the bottom right of the
display.
h
You can only enable or disable parameter access via the
FUNCTION RELAYS menu or by using the "+" or "–"
parameter set characters respectively in the circuit
diagram.
Changing parameters