Emergency Calls (Dsc Distress/Urgency/Safety Calls); Safety Or Urgency Calls To An Individual Station - JRC JSS-2150 Instruction Manual

Mf/hf radio equipment
Hide thumbs Also See for JSS-2150:
Table of Contents

Advertisement

4.5 Emergency calls
In emergency, the DSC is available for safety, urgency calls, or distress alerts. For safety and
urgency calls, either individual or area calls is selectable for the type of call. For distress alerts,
enabled to send either after entering the nature of distress or frequency, or without entering
anything. In both cases, pressing the
4.5.1

Safety or urgency calls to an individual station

Procedure
The procedure to send the safety or urgency
individual call is similar to the routine call except
selecting the call type to SAF/Indv/TEL or
URG/Indv/TEL (instead of TEL, ARQ or FEC also
available) and normally using the distress and
safety frequencies prior to other frequencies.
- Both calls of the safety test and the safety position request are described below.
Note
- When calling a coast station with requesting the working frequency, input "0" in
the Tx and Rx frequency input field to send the own position data.
4
.
5
.
1
.
1
Special safety individual calls
4
.
5
.
1
.
1
(1)
Safety test calls
Procedure
1 1
. .
1
.
Select SAF/Indv/Test in the Call type field
and input address.
Also change the Calling FRQ if needed.
2 2
. .
2
.
Press ENT on the Call to start sending
the safety test call.
After checking the channel free, the safety
test call is sent and the screen at right is
displayed.
(DSC distress/urgency/safety calls)
DISTRESS
key is required to send the distress alert.
1)DSC non-distress call
Call type
:[SAF/Indv/TEL
Address
:[
Calling FRQ:[ 2187.50kHz]
Working FRQ:[ 2182.00kHz]
[Call]
[Preview]
[Cancel]
1)DSC non-distress call
Call type
:[SAF/Indv/Test ]
Address
:[
Calling FRQ:[ 2187.50kHz]
[Call]
[Preview]
[Cancel]
Operation
]
]
]