TCS AVD Series Product Information

Front door station with integrated code lock

Advertisement

Quick Links

Product information
Front door station series AVD/AVE
with integrated code lock

Advertisement

Table of Contents
loading

Summary of Contents for TCS AVD Series

  • Page 1 Product information Front door station series AVD/AVE with integrated code lock...
  • Page 2: Table Of Contents

    Table ofcontents Scope of delivery ................................4  introduction .................................. 4    Notes on this product information..................................4   Used symbols and warning notices ..................................4   Further used symbols ......................................4 Safety instructions ............................... 5    General safety regulations ....................................5  ...
  • Page 3   Door release in basic mode ....................................21   Switching the light in basic mode ..................................21 Repair ..................................21    Exchanging the EEPROM storage ..................................21 FAQ ..................................... 22    Error indication/detection ....................................22 Cleaning ..................................22  Conformity ................................. 22  Information on disposal .............................
  • Page 4: Scope Of Delivery

    Scope of delivery AVD/AVE with code lock (AVD54013, AVE54043, AVE54063, AVE54083, AVE54103, AVE54123) allen key DIN 911 screw driver with round handle name plates, with light symbol product information, programming table introduction Notes on this product information This product information refers exclusively to qualified electricians. The product information of the video front door station series AVD/AVE contains important notes on intended use, installation and commissioning.
  • Page 5: Safety Instructions

    Observe the safety regulations according to DIN VDE 0100, when working on main power connections of 230 V. When installing TCS:BUS systems the general safety regulations for telecommunication systems ac- cording to VDE 0800 must be observed. Inter alia:  separated cable routing of high and low voltage lines ...
  • Page 6: Product Description

    Product description Intended use The video front door station series AVD/AVE with integrated code lock is suitable for surface-mount in the outdoor area. Modifications and repair of the device are only permitted, as far as described in this product information and executed by qualified electrician.
  • Page 7: Device Overview

    Device overview microphone drain for condensed water front panel lower aperture EEPROM bell button connection terminal connection for Service Device / bell button extension two-coloured LED nameplate illumination Code lock keypad volume control microphone bipolar pluggable screw terminal volume control loudspeaker cable gland loudspeaker attachment hole...
  • Page 8: Indication And Operating Elements

    Indication and operating elements Term Function LED is OFF device is in basic mode, no error is detected ON (lights up for 3 s) ∙ positive input confirmation LED green ∙ code number accepted (can be deactivated, adjustable lighting duration) BLINKS: device is in programming mode ON (lights up for 3 s): ∙...
  • Page 9: Installation

    Installation Observe when installing further devices, that you can pull out the name plate glass downwards. Do not mount another device below a device. Installation site To achieve an optimal video image quality do not point out the camera to ...
  • Page 10: Connecting The Lines

    Use only connecting lines made of the same material and with the same diameter within one terminal contact. Detailed information on wire routing in TCS systems as well as on the loop resistance you'll find in the system manual. Available under: http://www.tcsag.de/download/kataloge-prospekte-flyer CAUTION! Device damage.
  • Page 11: Example Circuit

    Example circuit Commissioning video WARNING! Danger to life due to electric shock First install all the devices of the system completely. Then switch on the mains voltage. ► Install the devices of the system completely. ► Do not connect V1 and V2 with the P-, a- or b-wire. Observe the polarity when connecting the video wires V1 (+) and V2 (−).
  • Page 12: Extended Code Lock Function

    Extended code lock function You can only use the extended code lock function for the first code (memory location). The function can be set with the configuration software configo You can connect a time switch (alternatively: motion detector, brightness sensor, door contact of a lock etc.) to the Device overview bipolar pluggable screw terminal (contacts 1 and 2, see ).
  • Page 13: Labelling The Name Plates

    (ill. 11). Print the name plates on the special foil. You can order the foil directly at TCS: Writeable polyester film for name plates DIN Configuration The front door station is to be configured as two separate devices: Front door station PES and code lock.
  • Page 14: Pre-Set Times

    Pre-set times relay switch time around 3 sec lighting duration of the LED relay switch time is adopted, around 3 sec (=255) duration of the acoustic acknowledgement 3 sec (= 255) Configuration options configo Function manually TCSK as of version 1.9.x.x AVD/AVE Programming the bell buttons Delete a bell button...
  • Page 15: Bell Button Programming

    ► Ensure that the access to the indoor station in the flat is granted. ► Check if the indoor station is connected to the TCS:BUS. ► Switch on the mains voltage. The operating LED at the power supply and control unit is on.
  • Page 16: Programming A Bell Button

    Programming a bell button Switching on the programming mode power supply and control unit Shortly press the RUN/PROG button. The LED blinks. The programming mode of the system is switched ON. 2a Programming via voice communication Establish a voice communication to the Shortly press the bell button at the A ring tone sounds at the front door and indoor front-door station.
  • Page 17 Repeat the programming of an already programmed bell button, always change only the second serial number. If you want to change the serial number that was programmed first, you have to delete both serial numbers and then reprogram both serial numbers. Switching on the programming mode power supply and control unit Shortly press the RUN/PROG button.
  • Page 18: Delete The Programming

    Delete the programming Before an already programmed bell button can be programmed newly, the programming must be deleted. Switching on the programming mode power supply and control unit Shortly press the RUN/PROG button. The LED blinks. The programming mode of the system is switched ON. Delete a bell button Press the bell button until the deletion tone sequence sounds.
  • Page 19: Initiate Programming

    Initiate programming Switching on and off the programming at the control unit: mode of the system ∙ Shortly press the RUN/PROG button, the LED blinks. ∙ Shortly press the RUN/PROG button, the LED lights up. At the Axx5xxx0: the two-coloured LED flashes green for 2 min Activate the programming mode of the device enter the master code (start with the pro-...
  • Page 20: Switch Off The Programming Mode

    Determine options Input: * 5 # option # value # option value 0 send light switch protocol 0 = no, 1 = yes (WE = 1) 3 acoustic acknowledgement 0 = off, 1 = on (WE = 1) buttons 4 programming mode can only 0 = no, 1 = yes (WE = 0) be activated after the pro-...
  • Page 21: Operating The Code Lock

    Operating the code lock Door release in basic mode Enter the access code enter the access code Correct input After entering the last number a positive acknowledgement tone sounds. The LED lights up green. The door opener is triggered. Note: If a code digit sequence is determined as a subset of another valid code digit sequence both sequences are acknowledged positively.
  • Page 22 Error pattern / problem / interfer- Possible causes Solution ence The lens of the camera fogs up. The The camera is not operated perma- Keep the camera running perma- video image is milky/blurred. nently. nently, because the device heat is sufficient to avoid fogging of the lens.
  • Page 23 Dispose the parts of the packaging in collecting tanks for cardboard and paper resp. plastics. Warranty We offer a simplified processing in case of warranty for qualified electricians.  Please contact the TCS HOTLINE under hotline@tcsag.de.  Our standard terms and conditions of sale you'll find under www.tcsag.de...
  • Page 24 Headquarters TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin | Germany FON: +49 (0) 3933/8799-10, FAX: +49 (0) 3933/879911, www.tcsag.de Subject to technical changes. TCS Hotline Germany time of printing: 02/2015 FON: +49 41 94 / 9 88 11 88, Fax: +49 41 94/ 9 88 129 Mail: hotline@tcsag.de...