Download Print this page

IBM System Storage EXN2000 Installation And Setup Instructions page 8

Advertisement

3
Installing the expansion unit into the rack
Caution:
DANGER:
or damaging an expansion unit, you must work with at least two other
people when you install an expansion unit in the rack. Do not remove the
disk drives to reduce the weight.
Note:
be correct and sequential in the individual loop(s). If the filer and expansion
unit were configured together by manufacturing, these IDs are already set.
The label on the front should match the switch on the back. For more
information, refer to the
3.1
3.2
3.3
6
32 kg (70.5 lb)
Use safe practices when lifting.
Expansion units are extremely heavy. To avoid injuring yourself
Verify the shelf IDs before installing into the rack. All shelf IDs should
EXN2000 Hardware and Service Guide
From the front of the rack, place the expansion unit onto the rails and
slide it in until the front mounting bracket of the expansion unit is flush
with the frame rails of the rack.
At the front of the rack, using four black hex head M5 screws in the H2
and H8 holes, secure the system unit to the rack by threading the screws
through the system unit bracket and the rack frame rail into the threaded
rail nuts. Tighten the screws using the 7mm nut driver.
From the rear of the rack, use two silver pan head M5 screws to attach
the rear of the chassis to the rails as shown below.
Screws
.

Advertisement

loading