FWE MOBILE REFRIGERATED AIR SCREEN
GENERAL OPERATION

TRANSPORTING

WARNING: Do not attempt to move the Air Screen Refrigerator until the unit is turned off, the power cord is
unplugged and out-of-the-way, or secured around rear handle.
A. Door must be securely shut and all caster locks released.
B. Maneuver unit by grasping the side handles or rear handle. CAUTION: The unit is designed for internal use
and not designed for outdoor all-terrain transport. Though the compressor has been located at the bottom of
the unit, lowering the center-of-gravity, the distribution of weight of the unit and food product makes the unit
top heavy. Be cautious when approaching uneven flooring (such as door sills, drains, thresholds, etc).

OPEN DOOR OPERATION

1. Set Temp. Pre-chill empty cabinet to minimum of 34°F to 36°F (1°C to 2.2°C) with door closed
minimum of one (1) hour.
2. Load cabinet from bottom to top with PRE-CHILLED FOOD AT 40°F (4.4°C) or colder.
Push trays to rear of wall.
FULL SWING DOOR WITH MAGNETIC HOLD OPEN CATCH:
Door opens to lay flat against cabinet and is secured by a magnetic door edge.
Note: Prior to "operating with door open", food product should be prechilled to an
internal food temperature of 36°F (2.2°C) or below.
3. After loading, close cabinet door and allow inside temperature to re-stabilize to designated
set temperature (or to desired internal temperature of food product).
4. Unload cabinet from top to bottom. Empty trays can be removed or left in the unit after unloading.
Trays will not appreciably effect the overall performance of the unit, however, keeping the 9 tray slides
racked in the cabinet after trays have been emptied of food product may result in slightly better performance.
5. This unit is equipped with an automatic condensate evaporator. To prevent water spills, leave unit plugged
in with door closed after use. A recommendation would be to defrost after use as well, to free coil from
ice build up formed during use.
6. This unit is equipped with a smart controller. During open door operation this unit knows the door
is open. When operating with door open the display will show "OPEN" and an internal count down
timer will start. This unit will allow open door operation for a maximum of 90 minutes. During the
90-minute open door operation this unit will not go into an auto or timed interval defrost cycle.
During open door operation the cooling system will remain on. This insures you will receive optimum open
door performance. If door is open longer than the allowed 90 minutes an open door alarm will be activated.
Display will flash "OPEN" and beep three times every ten seconds. To terminate the open door alarm the door
must be closed and remain closed for five minutes. If door open alarm is activated, unit will activate a hard
defrost cycle five minutes after door is closed.
7. INTERNAL CABINET TEMPERATURE WILL ELEVATE DURING DEFROST CYCLE.
8. For performance values with door open, see page 7.
9. For trouble shooting and addressing performance issues, see page 12.