Pregrammable Amplifier
TMB 100, 100-1 & TMB 100S
M
e
n
u
s
M
e
n
u
s
M
e
n
u
s

Config menu

This menu allows:
Configuration of filter distribution on UHF1, 2 and 3 inputs.
Switch on/off the input amplifiers
Selection of remote power supply (12 or 24 VDC).
Select the remote power for the UHF inputs
To limit the UHF channels at channel 60
Import or export a configuration file
Activate the PIN code menu
Select the language
Display the internal temperature

Configuration of filter distribution

Unit in standby mode, push a button to reach the CONFIG menu.
Press the enter button to reach the Comb menu.
Press enter again to change the configuration of the UHF inputs (part of the
display flashes)
Press the buttons + or - to select the distribution of the filters over the UHF inputs.
Confirm by pressing enter
Notes:
Each UHF filter can be deactivated. Just configure the filter in question to the value "off".
Input
Number of filters per
UHF input
Comb 0010
Ampx on/off
12 or 24 VDC
VDCx on/off
LTE on / off
Import/Export
Ang/Esp
UHF1
UHF2
UHF3
3
5
1
7
0
8
3
0
1
0
0
0
10
2
2
2
7
9