UART
Changed baud rate is enabled when restart the camera after save the baud rate setting to the flash memory on the camera by
selecting "DSP->FLASH" button.
Mirror/Flip
Set the image output with the horizontal flip, vertical flip or horizontal and vertical flip.
Sharpness / Contrast / Brightness / Negative-positive
Adjust each setting for the image.
Pattern Generator
Select the test pattern output.
Noise reduction
Brightness Y-NR
This function keeps the edge component for the middle component of the brightness and the noise reduces at less edge
component.
Pixel correlation Y-NR
Pixel correlation Y-NR uses 9x9 next same color pixel and subtracts the same color pixel between the target pixel and
around pixel.
Check the subtract with the threshold then the subtract is greater than the threshold then apply the average add to reduce
the noise.
Pixel correlation Y-NR function is good function for reduce the noise on the human skin.
Horizontal C-NR
The edge component keeps when the brightness is changed. If the brightness does not change, the noise is strongly
reduce at similarity area.
Vertical 3Line C-NR
The noise reduces by the flatten process for the microscopic chroma change of the vertical direction.
Vertical IIR C-NR
Observes the vertical direction pixels then control the color gap of the vertical direction.
STC-S133MIP
Product Specifications and User's Guide
No.17S023-02