Advertisement

Quick Links

User Manual
T-Rex
Models:
T-REX-115, TREX-JR-115
REV. 4/14/20
13655 Stowe Dr. Poway, CA 92064
P: (858) 679-1191
F: (858) 726-6005
www.mytee.com

Advertisement

Table of Contents
loading

Summary of Contents for Mytee T-REX Series

  • Page 1 User Manual T-Rex Models: T-REX-115, TREX-JR-115 REV. 4/14/20 13655 Stowe Dr. Poway, CA 92064 P: (858) 679-1191 F: (858) 726-6005 www.mytee.com...
  • Page 2 If there are questions regarding maintenance, replacement, or ordering parts please contact an authorized Mytee Products Service Center. To see an updated list please visit our website at https://www.mytee.com/support/find-distributors/. Before using your Mytee product, please read this manual thoroughly.
  • Page 3: Table Of Contents

    Table of Contents Important Safety Information At a Glance 1.1 - Technical Specifications 1.2 - Included with the T-Rex 1.3 - T-Rex Front View Machine Operation 2.1 - Powering the T-Rex 2.2 - Installing the Cleaning Head 2.3 - Connecting the Hoses 2.4 - Lowering the Handle 2.5 - Switching On the T-Rex 2.6 - Cleaning With the T-Rex...
  • Page 4: Important Safety Information

    This machine must be grounded. If it should malfunction When and if calling Mytee for support, please have your or break down, grounding provides a path of least resis- Model and Serial Number available for faster assistance.
  • Page 5 Important Safety Information 3. Always unplug power cord from electrical outlet before attempting any adjustments or repairs. 4. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. 5. Do not pull or carry by cord. Do not close a door on cord or pull cord around sharp edges or corners.
  • Page 6: At A Glance

    1 - At a Glance 1.1 - Technical Specifications 15” T-Rex 12” T-Rex Jr. Cleaning Path 15” Cleaning Path 12” Jets Jets 6x .01 4x .01 Vacuum 6x Positive Vetilation™ vacuum slots Vacuum 4x Positive Vetilation™ vacuum slots Speed Speed Adjustable 60-160 RPM Adjustable 80-180 RPM Motor...
  • Page 7: T-Rex Front View

    1 - At a Glance 1.3 - T-Rex Front View 1. Solution spray lever 8. Cleaning head 2. Safety lockout switch 9. Rotary union 3. Solution hose quick disconnect fitting 10. Motor 4. Motor speed control knob 11. Power cord pigtail 5.
  • Page 8: Machine Operation

    2 - Machine Operation 2.1 - Powering the T-Rex ♦ quick disconnect fitting coming from the handle. Plug the female end of 2.4 - Lowering the Handle the extension cord into the pigtail on the T-Rex. Next plug the male end of the extension cord into a standard, grounded outlet.
  • Page 9: Cleaning With The T-Rex

    2 - Machine Operation ♦ It may be easiest to set motion. the motor speed to the 2.7 - After Cleaning lowest setting using the knob on the front of the After cleaning, switch off the T-Rex by releasing the handle before switching the power switch lever.
  • Page 10: Machine Maintenance

    3 - Machine Maintenance 3.1 - Lubricating the Felt Vacuum Seal In order to keep the T-Rex running smoothly and reduce the risk of damage to the machine and subsequent downtime, Mytee recommends following the mainte- nance schedule below: Maintenance Item Daily...
  • Page 11: Troubleshooting

    4 - Troubleshooting Motor fan is spinning but cleaning head is not. Possible Cause Solution Pinion gear has broken. Replace the pinion gear. (Part #H129) Machine power is powering the control board, but unit will not run. Possible Causes Solutions A power cord could be Check all cord connec- disconnected.
  • Page 12 NOTES Mytee Products, Inc. 13655 Stowe Dr. Poway, CA 92064 www.mytee.com © 2020 Mytee Products, Inc. Printed in the USA...

This manual is also suitable for:

T-rex-115Trex-jr-115