TROUBLESHOOTING

The following items are the most common dispenser symptoms if problems occur. For
symptoms or remedies not shown, contact your Signode service representative for additional
information and details. The following dispenser symptoms are shown in this manual:
#1 SYMPTOM - Loose strap between idler wheels.
#2 SYMPTOM - Strap between dispenser and machine too loose following strapping cycle.
#3 SYMPTOM - Loose wraps on strap coil.
#4 SYMPTOM - Dispenser "Jerk" Stops.
#5 SYMPTOM - Dispenser "Jerk" Starts.
#6 SYMPTOM - Dancer arm swings upward with little or no resistance.
#1 SYMPTOM: Loose strap between idler wheels.
CAUSE
Dispenser brake improperly adjusted.
#2 SYMPTOM: Strap between dispenser and machine too loose following strapping cycle.
CAUSE
Dispenser brake improperly adjusted.
#3 SYMPTOM: Loose wraps on strap coil.
CAUSE
1.
Brake block pressure too low.
2.
Brake block friction surface worn out.
#4 SYMPTOM: Dispenser "Jerk" Stops.
CAUSE
Brake block pressure too high.
REMEDY
Adjust brake as required.
REMEDY
Adjust brake as required.
REMEDY
1.
Increase brake block pressure, See
brake adjustment procedure.
2.
Rotate brake block 180° to new friction
surface.
REMEDY
Reduce brake block pressure. See brake
adjustment procedure.
18