Description; Refrigeration Unit; General Notes; Extract From Our General Conditions Of Guarantee - Viessmann FT 0700 Assembly And Operation Manual

Ceiling-mounted refrigeration units
Table of Contents

Advertisement

1.

Description

The units have been designed for the temperature range
given. If they have been operating outside of the given
range for a number of days, a serious fault in the unit must
be considered.
1.1
Deep-freezer refrigeration units
FT 0700, FT 1000, FT 1200, FT 1500
The units are designed for refrigeration of rooms in which
goods are kept at temperatures between -1°C and -25°C.
1.2

Refrigeration unit

CT 0900, CT1200, CT1500, CT 2000, CT 3000
These units are designed for refrigeration of rooms in which
goods are kept at temperatures between -5°C and +19°C.
2.

General Notes

2.1
Extract from our conditions of guarantee
The guarantee is for one year. The period begins on the day
of delivery, as shown in the delivery note or invoice. Within
the period of guarantee, functional faults resulting from bad
quality or materials will be repaired free of charge.
Other claims resulting, especially those relating to
consequential damages, cannot be recognized.
No guarantee will be assumed for damage resulting form
improper use or operation, or improper assembly on the
part of the buyer or other parties, or for natural
depreciation, improper or careless handling, or for chemical,
electrochemical or electrical damage insofar as these do not
result from our own actions , or from non-attention to the
directions for assembly, operation and maintenance, or
from improper changes or repairs to the equipment by the
buyer or third parties, or resulting from parts supplied by
other companies. The guarantee is invalid if the coolant
circulation system is opened by unauthorized personnel, or
by interference with the system, or if the serial number of
the unit is changed or made unreadable.
General notice (liability): the details of this technical documents serve for description. Consents regarding the availability of certain features or
regarding a certain purpose always require a special written agreement.
Page 3 GB
2.2

Norms and regulations

At the time of production, the unit has been built and
tested according to the valid norms and regulations.
It complies with the
EMC Directive 2004/108/EC,
machinery directive 2006/42/EG.
The unit has been inspected at the factory for refrigerati-
on circulation leakage and for function.
2.3
Requirements for installation area / Intended use
The refrigeration unit may not be installed outdoors.
For economical operation, the temperature of the
surroundings of the unit should be from +5°C to +25°C.
The relative humidity of the room should not exceed
80%.
The room must be well-ventilated in order to ensure
release of heat. Avoid a direct source of heat near the
unit. Heating of the room must be avoided as this will
reduce the cooling efficiency and increase power usage.
The refrigeration unit is designed to allow open suction
and blow-off of air. If air ducts are required, a
refrigeration specialist must be consulted.
Sufficient free space must be provided for the ventilation
openings of the unit to guarantee proper ventilation.
- at least 600 mm from all ventilation openings
If this distance cannot be maintained, suitable measures
must be taken to guarantee proper ventilation
(air deflectors, ducts, additional fans).
Do not use the unit in areas in which strong magnetic
impulses can be expected or near radio antennae.
1 - 2.3
GB
Right reserved to make technical changes!