4-15-2. SWITCH FUNCTION (INDOOR UNIT)
DIP SWITCH SETTING
SW1-1. Auto restart setting
Auto restart function can be selected by turning this switch ON/OFF.
AUTO RESTART SETTING
SW 1-1
OFF
ON
SW1-2, 1-3. Room temperature correct coefficient of heating.
Decide the heating temperature correct coefficient value of heating.
TEMPERATURE CORRECTION
SW 1-2
SW 1-3
OFF
ON
OFF
ON
SW4-1. Dip SW 4-1setting forbidden
SW 4-1
SW4-2, 4-3. Ceiling height setting
Ceiling height ft. (m)
8ft. 2-7/16in. to 9ft. 10-1/8in. (2.5 to 3.0)
9ft. 10-1/8in. to 11ft. 5-25/32in. (3.0 to 3.5)
More than 11ft. 5-25/32in. (3.5)
Less than 8ft. 2-7/16in. (2.5)
If the setting for a low ceiling is selected, the capacity of the air
conditioner decreases slightly.
(
Factory setting)
SW state
Invalidity
Validity
(
Factory setting)
SW state
heating
dry
OFF
+3.6degF
-3.6degF
OFF
-3.6degF
-3.6degF
ON
0 degF
0 degF
ON
+7.2degF
0 degF
(
Factory setting)
OFF
cooling
-3.6degF
-3.6degF
0 degF
0 degF
Normal
High ceiling 1
High ceiling 2
Low ceiling
- (04 - 27) -
(
Factory setting)
DIP - SW4
1
2
3
-
OFF
OFF
-
ON
OFF
-
OFF
ON
-
ON
ON