Chino IR-SA Series Instructions Manual

Infrared radiation thermometer for processing

Advertisement

Quick Links

INST.No.INE-510-P6
IR-SA Series
Infrared radiation thermometer for
Processing
Always keep this instruction manual with the unit.
P l e a s e b e s u r e t o d e l i ve r t h i s i n s t r u c t i o n m a n u a l
wi t h t h e u n i t t o t h e e n d u s e r.
Model : IR-SAI
IR-SAS
IR-SAH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IR-SA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chino IR-SA Series

  • Page 1 INST.No.INE-510-P6 IR-SA Series Infrared radiation thermometer for Processing Model : IR-SAI IR-SAS IR-SAH Always keep this instruction manual with the unit. P l e a s e b e s u r e t o d e l i ve r t h i s i n s t r u c t i o n m a n u a l...
  • Page 3: Table Of Contents

    INST.No.INE-510-P6 CONTENTS 1. Introduction......1 7. Maintenance and check ..13 1.1 General ........... 1 7.1 Periodical checking… ......13 7.2 Trouble shooting ........13 2. Model........1 7.2.1 Measuring value not displayed or 2.1 Model............1 displayed lower ..13 2.2 Belongings ..........
  • Page 4 ∙ Do not store the thermometer in hot and humid places. ∙ For failures of the thermometer, don’t overhaul it by yourself, and contact your sales agent of CHINO Corporation. Symbols in this instruction manual The symbols shown below are used depending on important degrees for using the thermometer safely and avoiding unexpected situations.
  • Page 5 Don’t use the thermometer if it was broken, smoking or nasty smelling. These may cause fire. For such abnormal condition, turn off the power switch at once and contact your sales agent of CHINO Corporation. Using “telescope” (Model: IR-ZYTS), do not see the object exceeding 1500ºC directly.
  • Page 6: Introduction

    INST.No.INE-510-P6 1. Introduction 1.1 General The IR-SA series is an infrared radiation thermometer. These thermometers has fixed focusing of long-distance factor, ability of working in 0 to 90ºC ambient temperature, for free installation. The radiation energy collected through the objective lens is transmitted to the element is converted into an electrical signal.
  • Page 7: Accessories Model

    INST.No.INE-510-P6 2.3 Accessories Model Accessories Model Reference Setting Parameter, display measurement value, Setting display unit IR-GZ and power supply to IR-SA □□□:length (m) Connecting cable IR-ZYRC□□□ 002:2m,005:5m,010:10m,020:20m,100:100m Telescope IR-ZYTS Insert to IR-SA, and bring the object into focus Laser pointer IR-ZYLZ1 Protective case IR-ZYCH...
  • Page 8: Names And Functions Of Component Parts

    INST.No.INE-510-P6 3. Names and functions of component parts 3.1 Overview (4) Inserting hall for telescope and laser pointer (5) Blind cap CHINO (3) Case (6) Connecter (1) Cover glass (outer) (7) Serial No.label (2) Object lens (inner) (8) Screw for instllatin fittings...
  • Page 9: Installation

    INST.No.INE-510-P6 4. Installation (refer to [3. Names and functions of component parts].) 4.1 Precautions in Installation This IR-SA series radiation thermometer is a sensitive instrument. Install it by referring to the following cautions. ● Vibration and impacts C aut ion Vibration or impacts reduces the liability of the thermometer and causes an unstable measurement by the targeting shake to a measuring surface.
  • Page 10: Installation

    Before install the thermometer, mount the installation fittings to the thermometer by using screw. And install the thermometer by using Instllation fittings CHINO installation fittings. Please read the operation manual for an accessory when instilling it by using the exclusive accessories.
  • Page 11: Measuring Distance And Measuring

    INST.No.INE-510-P6 4.3 Measuring distance and measuring diameter The relation of the measuring distance and the measuring diameter is indicated in figure below. IR-SA□10N φ 20 φ 10 φ 5 1000 IR-SA□11N φ 30 φ 10 φ 10 1000 2000 IR-SA□12N φ...
  • Page 12 INST.No.INE-510-P6 IR-SA□20N φ 10 φ 15 φ 3 1000 IR-SA□21N φ 20 φ 10 φ 5 1000 2000 IR-SA□I22N φ 30 φ 10 φ 10 2000 4000 IR-SA□25N (Option) φ 60 φ 25 φ 10 5000 10000 IR-SA□2SN (Option) φ 10 φ...
  • Page 13 INST.No.INE-510-P6 At focusing position of object lens, the relation of measuring distance and the measuring diameter are defined by the distance factor as shown in the following formula. Measuring diameter (mm) = Measuring distance (mm)/distance factor In case of IR-SA, distance factor and focusing position of object lens are shown in model name, the number of next beginning of alphabet shows it, and next number shows focusing position of object lens.
  • Page 14: Targeting

    INST.No.INE-510-P6 4.4 Targeting Before beginning the measurement, please point the thermometer to the measurement object and install it. Telescope (model: IR-ZYTS (option)) and laser pointer (model: IR-ZYLZ1(option)) enable more correct targeting. You can confirm the center of the measurement object, by using telescope or laser pointer. 4.4.1 Telescope (Model : IR-ZYTS) !...
  • Page 15: Laser Pointer (Model : Ir-Zylz1)

    INST.No.INE-510-P6 4.4.2 Laser pointer (MODEL : IR-ZYLZ1) ! (7)Battery lid (2)Main body fixation screw (5)Switch (3)Focusing ring (4)Body (6)Battery case (1)Prevention of loser screw 1) Please remove blind cap of the thermometer counterclockwise, and insert laser to insert hall for telescope and laser pointer.
  • Page 16: Connections And Wirings

    When the connecter of the cable (IR-ZYRC) is connected, and the coupling ring is tightened, the waterproof of the IR-SA series is achieved. There is no waterproof property in the connecter of the thermometer in the state that the cable is not connected.
  • Page 17: Operation

    INST.No.INE-510-P6 6. Operation In case of IR-SA, parameter setting, the measurements indication are performed entirely setting display unit (model : IR-GZ). For details, refer to instruction manual of setting display unit (model : IR-GZ). 6.1 Self-diagnostic function In IR-SA, self-diagnosis function is built-in. On abnormal conditions, an ERR00 will be displayed in IR-GZ.
  • Page 18: Maintenance And Check

    INST.No.INE-510-P6 7. Maintenance and check 7.1 Periodical checking… Check the followings periodically or if required. •Lens: Check the objective lens for dust or dirty. If dirt is present, remove it with a blower for camera lens. If the dirt cannot be removed with the blower, wipe the lens gently with cotton ball soaked in alcohol.
  • Page 19: Reference

    INST.No.INE-510-P6 8. Reference The emissivity are values determined by the material of object, profile of its surface, surface roughness, oxidized or not, measuring temperature, measuring wavelength and other factors. They are represented by the thermal radiation ratio "" when a black body furnace at the same temperature is measured in the same wavelength band.
  • Page 20: Emissivity Table (= 0.9Μm)

    INST.No.INE-510-P6 8.1.2 Emissivity table 8.1.3 Emissivity table (= 0.9µm) (= 1.55µm) Metal Emissivity Metal Emissivity Aluminum 0.10 to 0.23 Aluminum 0.09 to 0.40 Gold 0.015 to 0.02 Chrome 0.34 to 0.80 Chrome 0.36 Cobalt 0.28 to 0.65 Cobalt 0.28 to 0.30 Copper 0.05 to 0.80 Iron...
  • Page 21: Emissivity Table (=2.0Μm)

    INST.No.INE-510-P6 8.1.4 Emissivity table (=2.0µm) Metal Emissivity Oxide Emissivity Aluminum 0.08 Aluminum 0.40 Copper 0.04 Copper 0.80 Gold 0.02 Lead 0.65 Magnesium 0.20 Magnesium 0.75 Silver 0.04 Molybdenum 0.80 Nickel 0.85 Silver 0.10 Alloy Emissivity 0.60 Chromel, Alumel 0.30 Brass 0.70 Inconel 0.30...
  • Page 22: General Specifications

    INST.No.INE-510-P6 9. General specifications 9.1 Thermometer Model IR-SAI IR-SAS IR-SAH 2-color radiation Measuring system Single-color radiation thermometer thermometer Detecting element InGaAs InGaAs/Si Measuring wavelength 1.55μm 0.9m 1.55m/0.9m Measuring range 300 to 1600ºC 600 to 2500ºC 900 to 2500ºC Less than 1500ºC : Less than 1000ºC : ±0.2% of readings ±2ºC ±0.5% of reading Accuracy ratings *1...
  • Page 23: Ir-Sai N, Ir-Sasn

    INST.No.INE-510-P6 9.2 IR-SAI N, IR-SAS Outside dimensions 2- M3 Depth6 Unit : mm 9.3 Accessories outside dimensions 9.3.1 Installation fittings (MODEL : IR-ZYHAW : BELONGINGS) Unit : mm 9.3.2 Connection cable (MODEL : IR-ZYRC) M3.5 Chip (40) L(m) Unit : mm -18-...
  • Page 24: Telescope (Model : Ir-Zyts)

    INST.No.INE-510-P6 9.3.3 Telescope (MODEL : IR-ZYTS) Unit : mm 9.3.4 Laser pointer (MODEL : IR-ZYLZ1) 290.5 Unit : mm 9.3.5 Fitting (MODEL : IR-ZYHG1) 27.5 4- φ 5.5 26.5 26.5 4- M4 6- M4 4- φ 7 1/4- 20UNC Unit : mm -19-...
  • Page 25: Fitting (Model : Ir-Zyhg2)

    INST.No.INE-510-P6 9.3.6 Fitting (MODEL : IR-ZYHG2) 60° 6- M4 Unit : mm 9.3.7 Universal head (MODEL : IR-ZMSS) 4- M5 4- φ 9 (187) Unit : mm -20-...
  • Page 28 32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 Telephone: +81-3-3956-2171 Facsimile : +81-3-3956-0915 Web site http://www.chino.co.jp/...

This manual is also suitable for:

Ir-saiIr-sasIr-sah

Table of Contents